5.2
Mounting rectangular devices
The sensors can be mounted in any position.
A 4-side flush mounting is possible. The switching distance is reduced if the device is mounted
from the rear or with a protrusion.
➤
➤
Clean the mounting surface and the surrounding area.
➤
➤
Install the sensor in a fixture (mounting bracket or fixing clamp) if necessary.
➤
➤
Install the sensor or the mounting fixture at the intended location. Observe the minimum
mounting distances and mounting conditions.
Distance Ni50U-… in rectangular design
D
240 mm
W
105 mm
S
60 mm
G
300 mm
N
30 mm
B
40 mm
Abb. 11: Minimum mounting distances