Operating Instructions

Inductive Sensors

uprox®  

with IO-Link Interface

Содержание uprox BI10U-M18 Series

Страница 1: ...Your Global Automation Partner Operating Instructions Inductive Sensors uprox with IO Link Interface...

Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com Contents...

Страница 3: ...s 11 4 2 1 Properties and features Rectangular design 11 4 3 Operating principle 11 4 4 Functions and operating modes 11 4 4 1 Sensor functions 11 4 4 2 Settable properties 13 4 4 3 Standard I O mode...

Страница 4: ...ction block 25 9 1 3 Process data 25 9 2 Setting in SIO mode 26 9 2 1 Setting the device before initial commissioning 26 9 2 2 Setting devices after initial commissioning 26 10 Troubleshooting 26 11 M...

Страница 5: ...ch if not avoided will result in death or serious injury WARNING WARNING indicates a possible hazardous situation with the risk of death or serious injury if it is not prevented NOTICE NOTICE indicate...

Страница 6: ...manual 1 4 Feedback about these instructions We make every effort to ensure that these instructions are as informative and as clear as pos sible If you have any suggestions for improving the design or...

Страница 7: ...r uprox or uprox 3 Faktor 1 sensors Rated switching distance Switching distance Functional principle i Inductive Installation B Flush N Non flush M18 Design Housing M Threaded barrel brass in mm MT Th...

Страница 8: ...he commission ing of your application The Turck product database offers you several software tools for pro gramming configuring or commissioning as well as data sheets and CAD files in many export for...

Страница 9: ...from strong magnetic fields The devices can be operated and set with IO Link masters compliant with specification 1 1 via an IO Link interface Process and diagnostics data can be exchanged during oper...

Страница 10: ...th the surrounding mounting area see chapt 5 2 All devices are provided with a metal bodied M12 connector plug for connecting the sensor cable The devices can be set and operated via an IO Link interf...

Страница 11: ...ontactless and wear free detection of metallic objects To do this the devices generate an electromagnetic field which interacts with the detected object The sensors of the uprox series have no reducti...

Страница 12: ...2nd bit Bit 3 0 0 0 1 1 0 3rd bit Bit 2 0 1 0 1 0 1 NOTE Output 2 can be configured as required or can be used as a temperature indicator The maximum switching frequency is reduced to 7 Hz in low reso...

Страница 13: ...on Output 2 The following output configurations can be set for output 2 PNP NO contact PNP NC contact NPN NO contact NPN NC contact Push pull non inverted Push pull inverted Temperature indicator not...

Страница 14: ...f the switch on delay Ton is activated the switching pulse is generated after the actual sensor actuation The switch on delay can be set between 0 60000 ms Abb 7 Switch on delay The set output configu...

Страница 15: ...actual value is above or below the set limits Application specific marking The device is provided with a 32 byte memory for application specific marking The first byte of the memory is transferred to...

Страница 16: ...log mode Temperature alarm for values above or below the set temperature limits Application specific marking Reading of IO Link parameter data All other sensor functions and settable features see chap...

Страница 17: ...U M18 BI10U MT18 10 Nm BI20U M30 BI20U MT30 50 Nm Clean the mounting surface and the surrounding area Install the sensor in a fixture mounting bracket or fixing clamp if necessary Install the sensor o...

Страница 18: ...h a half shell clamp NOTICE Mounting with a half shell clamp Device damage due to faulty mounting Align the uprox marking on the front cap of the sensor horizontally in relation to the half shell clam...

Страница 19: ...from the rear or with a protrusion Clean the mounting surface and the surrounding area Install the sensor in a fixture mounting bracket or fixing clamp if necessary Install the sensor or the mounting...

Страница 20: ...metal X 10 mm 20 mm X 20 mm 20 mm X 30 mm 20 mm X 40 mm 20 mm Protruded on metal Y 10 mm 40 mm Y 20 mm 50 mm Y 30 mm 50 mm Y 40 mm 50 mm Mounting in aperture plate I 150 mm Installation with twisted...

Страница 21: ...ace left Active face right Active face up Active face down Gently press together the fixing clamp on the mounting bracket to release the device from the mounting bracket Turn the active face to the si...

Страница 22: ...irections Active face front as supplied Active face left Active face right Active face up Active face down Undo the locking screw B and pull the sensor from the mounting bracket A Undo the screws to E...

Страница 23: ...ring diagram 7 Commissioning The device is operational automatically 18 ms after the cables are connected and the power supply is switched on If the device is connected to an IO Link master IO Link co...

Страница 24: ...during com missioning as well as during operation NOTE The change of the output configuration is only updated after a voltage reset or after switching to SIO mode 8 3 Operating devices in SIO mode In...

Страница 25: ...0 Output 2 not actuated 1 Output 2 switches depending on the sensor function and the output configuration 1 Output 2 is not set as a temperature indicator One switch point sensor function 2 Switch po...

Страница 26: ...se the device at another location in the application The sensor has a fault if it is still present Take the device out of service and replace it with one of the same type If the device operates troubl...

Страница 27: ...rom the device Undo the connections of the device or if necessary the mounting aid for the mounting area Undo if necessary the connection of the device to the mounting aid 14 Disposal The devices are...

Страница 28: ...age reverse polarity protection yes completely Output function 4 wire NO contact N O contact PNP NPN Push pull IO Link Output 1 Switching output or IO Link mode Output 2 Switching output Switching fre...

Страница 29: ...pletely Output function 4 wire NO contact N O contact PNP NPN Push pull IO Link Output 1 Switching output or IO Link mode Output 2 Switching output Switching frequency max 0 5 kHz IO Link specificatio...

Страница 30: ...Short circuit protection Yes cyclic Voltage drop at Ie 1 8 V Wire breakage reverse polarity protection yes completely Output function 4 wire NO contact N O contact PNP NPN Push pull IO Link Output 1 S...

Страница 31: ...31 2016 08 uprox Sensors with IO Link Interface...

Страница 32: ...D102217 2016 08 D102217 1608 28 subsidiaries and over 60 representations worldwide www turck com...