![turck TBIL-M1-16DXP Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/turck/tbil-m1-16dxp/tbil-m1-16dxp_instructions-for-use-manual_1181822015.webp)
V01.10 | 2020/11
15
Manual output reset after overcurrent – 0x44 (68), sub index 0
This parameter defines if a manual reset is necessary after an overcurrent occurred at the digital
channel.
Format
Length
Byte
2 byte
1 bit per channel
The default values are written in
bold
.
Value
Meaning
0
No
Automatic recovery mode
1
Yes
Controlled recovery mode (output has to be reset manually)
NOTE
This parameter can also be set for all connectors of the module via the IODD.
Byte 0
Byte 1
Bit offset
Bit offset
7
6
5
4
3
2
1
0
15
14
13
12
11
10
9
8
Sub index
Sub index
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
C8P2
(B)
C8P4
(A)
C7P2
(B)
C7P4
(A)
C6P2
(B)
C6P4
(A)
C5P2
(B)
C5P4
(A)
C4P2
(B)
C4P4
(A)
C3P2
(B)
C3P4
(A)
C2P2
(B)
C2P4
(A)
C1P2
(B)
C1P4
(A)