Technical data
132
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
Technical Data
Configuration Assembly Instance
106
PROFINET
PROFINET specification
V 2.35
Conformance Class
B (RT)
Address assignment
DCP
MinCycle Time
1 ms
Fast Start-Up (FSU)
< 150 ms
Diagnostics
according to PROFINET Alarm Handling
Topology detection
Supported
Automatic address assignment
Supported
Media Redundancy Protocol (MRP)
Supported
System redundancy
S2
Network load class
3
Digital inputs
Number of channels
4 DXP and 4 SIO
Input type
PNP
Type of input diagnostics
Channel diagnosis
Switching threshold
EN 61131-2 type 3, PNP
Signal voltage, low level
< 5 V
Signal voltage, high level
> 11 V
Low level signal current
< 1.5 mA
High-level signal current
> 2 mA
Input delay
0.05 ms
Potential isolation
Galvanic isolation to P1/P2,
voltage proof up to 500 V AC
Digital outputs
Number of channels
4 DXP
Output type
PNP
Type of output diagnostics
Channel diagnostics
Output voltage
24 VDC from potential group
Output current per channel
0.5 A, short-circuit-proof
Potential isolation
Galvanic isolation to P1/P2,
voltage proof up to 500 V AC
IO-Link
Number of channels
4
IO-Link
Pin 4 operated in IO-Link mode
IO-Link specification
Version 1.1
IO-Link port type
Class A
Frame type
Supports all specified frame types
Supported devices
Max. 32 byte input/32 byte output
n
Input data
n
max. 32 Byte per channel
n
Output data
n
max. 32 Byte per channel