Operating
Process input data
116
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
10
Operating
10.1
Process input data
Word
no.
Bit no.
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Basic
0x00
-
-
-
-
-
-
-
-
DXP7 DI6
(SIO)
DXP5 DI4
(SIO)
DXP3 DI2
(SIO)
DXP1 DI0
(SIO)
0x01
-
-
-
-
-
-
-
-
-
DVS6 -
DVS4 -
DVS2 -
DVS0
IO-Link process input data
0x02
…
0x11
IO-Link port 1,
structure depends on the channel parameterization (0…32 byte per channel)
0x12
…
0x21
IO-Link port 2,
structure depends on the channel parameterization (0…32 byte per channel)
0x22
…
0x31
IO-Link port 3,
structure depends on the channel parameterization (0…32 byte per channel)
0x32
…
0x41
IO-Link port 4,
structure depends on the channel parameterization (0…32 byte per channel)
Diagnostics
DXP channels
0x42
-
-
-
-
-
-
-
-
ERR
DXP 7
-
ERR
DXP 5
-
ERR
DXP 3
-
ERR
DXP 1
-
IO-Link port 1
0x43
GEN-
ERR
OVL
V
HIGH
V
LOW
ULVE LLVU O
TMP
PRM
ERR
EVT1 EVT2 PD
INV
HW
ERR
DS
ERR
CFG
ERR
PPE
-
0x44
IO-Link port 2, assignment similar to port 1
0x45
IO-Link port 3, assignment similar to port 1
0x46
IO-Link port 4, assignment similar to port 1
IO-Link Events
0x47
Port (1st Event)
Qualifier (1st Event)
0x48
Event Code low byte (1st Event)
Event Code high byte (1st Event)
…
0x65
Port 16th Event)
Qualifier (16th Event)
0x66
Event Code low byte (16th Event)
Event Code high byte (16th Event)
Module status (status word)
0x67
-
FCE
-
-
-
COM V1
-
V2
-
-
-
-
-
-
DIAG
Содержание TBEN-S2-4IOL