turck 3 IMX12-FI01-1SF-1R-0/24VDC/CC Скачать руководство пользователя страница 7

V01.00 | 2020/04 

4.1 

Safety function

IMX12-FI01-1SF-1R
IM12-FI01-1SF-1R

The measured or monitored value at input [E1] are transmitted to the output [A1D] according to 
parameterization and within the local process safety time observing the permissible safety accuracy. 

Local process safety time is:

 

fin > 1,124 Hz: 1 s

 

fin < 1,124 Hz: 1/f+110 ms 

The power bridge is not part of safety-function.

The LED are not part of the safety-function.

The common alarm output is not part of safety function.

Two devices must not be used for the safety-function, e. g. to increase the hardware fault toler-

ance to achieve a higher SIL.

A 1oo2 architecture does not achieve a SIL3.

The safety function is executed 2 s after power-on.

The frequency limits for the inputs are:

 

NAMUR-Sensors according to EN 60947-5-6, line monitoring ,1 µHz …10 kHz, pulse pause 

ratio > 50 µs

 

PNP/NPN-sensors, 1 µHz … to 10 kHz, pulse pause ratio > 50 µs

 

potential free contacts, 1 µHz … 10 kHz, pulse pause ratio > 50 µs

 

external signal source, 1 µHz … to 10 kHz, pulse pause ratio > 50 µs

 

ū

0-signal 0…3 V

 

ū

1-signal 5…30 V

The local process safety time is the periodical internal diagnostic check (900 ms) + reaction 

time. 

4.2 

Safety accuracy

The safety accuracy Δ

total

 depends on the variant and its configuration.

In order to evaluate the safety accuracy for an individual configuration the following informa-

tion is required:

 

Δ

[Ex]

 is < 0.1 % of input frequency

Assignment [E] to [A]

Δ

total

[E1] 

 [A1D] 

Δ

total

 = Δ

[E1]

4.3 

Safe state

IMX12-FI01-1SF-1R
IM12-FI01-1SF-1R

The safe state is defined as the output is de-energized (A1D).

4.4 

Alarm state

Internal diagnostics are provided in order to detect random hardware failures that result in 

a failure of the function. If a failure is detected the device goes into the alarm state. The time 

between the occurance of the failure and the time to achieve the alarm state is less than 1 s.  

The device remains in alarm state as long as the failure persists, at least for 1 s.

IMX12-FI01-1SF-1R
IM12-FI01-1SF-1R

The alarm state is defined as the output is de-energized (A1D).

Содержание 3 IMX12-FI01-1SF-1R-0/24VDC/CC

Страница 1: ...Your Global Automation Partner Safety Manual IM X 12 FI01 1SF 1R Frequency Transducer...

Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com Contents...

Страница 3: ...r using the results 9 5 4 1 Probability of dangerous failure per hour High Demand Mode 9 5 4 2 Average probability of dangerous failure on demand Low Demand Mode 10 6 Operation Instructions 11 6 1 Gen...

Страница 4: ...4 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...

Страница 5: ...sh version of the safety manual or contact Turck directly 2 Scope This safety manual is valid for the following devices Product Number Product Name Number of Channels Terminal Block Design Power Bridg...

Страница 6: ...tential free contacts up to 10 kHz Outputs Common alarm output MOSFET potential free Relay output SPDT monitoring overshoot undershoot and window limits working direction adjustable reaction time digi...

Страница 7: ...ee contacts 1 Hz 10 kHz pulse pause ratio 50 s external signal source 1 Hz to 10 kHz pulse pause ratio 50 s 0 signal 0 3 V 1 signal 5 30 V The local process safety time is the periodical internal diag...

Страница 8: ...directly 5 1 Architectural specifications Due to architectural considerations the following characteristics are specified Type B HFT 0 Experience has shown that the useful lifetime often lies within...

Страница 9: ...29500 based on the average ambient temperature of components of 40 C No effect is a failure mode of a component that plays part in implementing the safety func tion but is neither a safe nor a danger...

Страница 10: ...Average probability of dangerous failure on demand Low Demand Mode With the FMEDA results and the values specified in the following table the average frequency of dangerous failure can be calculated...

Страница 11: ...om the temperature in the control cabinet The temperature on the exterior sidewall of the housing must be observed in a steady state In case the temperature on the exterior sidewall of the housing is...

Страница 12: ...Connection and Wiring Diagrams on page 20 Use cables with terminal cross section rigid 0 2 mm2 to 2 5 mm2 or flexible 0 2 mm2 to 2 5 mm2 When wiring with stranded wires Fix the wiring ends with ferrul...

Страница 13: ...Pull the screwdriver to fix the cable ends Fig 3 Connection with spring type terminals Make sure that only suitable equipment e g sensors are connected to the device see Ap pendix Connection and Wirin...

Страница 14: ...Voltage signal 0 signal 0 3 V 1 signal 5 30 V 3 wire PNP 3 wire sensor positive negative positive 0 signal sensor not actuated 0 V 1 signal sensor actuated 12 V 3 wire NPN 3 wire sensor negative posi...

Страница 15: ...g behavior when inversion is deactivated Fig 4 2 point mode 4 point In 4 point mode a window with a lower and upper hysteresis is formed The switch points must fulfill the following condition BotOff B...

Страница 16: ...x BotOn Inv G 1 1 2 H 100 0 BotOff Inv G 1 H 100 TopOff Inv G 1 H 100 TopOn Inv G 1 1 2 H 100 fmax Locking function This parameter depends on the physical state of the relay Parameter Inversion is reg...

Страница 17: ...cy is higher than the adjusted value the device falls into the safe state Config If the parameters are set push config button between 2 and 6 seconds In this way the device takes over the set values I...

Страница 18: ...lly charging cleaning agent Perform proof tests after each cleaning see Appendix Proof Test on page 22 The device must be replaced before remaining longer than 24 h within the safe state due to an int...

Страница 19: ...19 V01 00 2020 04 6 5 After operation Undo the terminal connection on the device Remove the device from its rail fixing as shown in the figure Fig 7 Remove device Ensure the dispose of the device...

Страница 20: ...rve The load curve of the relay A1D must be observed The relay must be protected against overcurrent IMX12 FI01 1SF 1R A 10 0 1 0 5 1 2 5 20 V 50 100 200 300 400 10 DC resistive load AC resistive load...

Страница 21: ...detected safe failure rate per hour MTTR Mean time to restoration hour PFDavg Average probability of dangerous failure on demand PFH Probability of dangerous failure per hour SFF Safe Failure Fraction...

Страница 22: ...ction 1 Bypass the safety functions and take appropriate action to avoid a false trip 2 Provide appropriate input control signals to the interface modules and verify the expected signal input output c...

Страница 23: ...23 V01 00 2020 04...

Страница 24: ...100017761 2020 04 100017761 Over 30 subsidiaries and over 60 representations worldwide www turck com...

Отзывы: