2.0.0 General information 

Turbovex  TX  350A  and  TX  75A  are  decentralized  ventilation  units  with  integrated  heat 
recovery. 

2.1.0 Preface 

This  installation  and  operation  guide  contains  technical  information  and  details  of 
installation and maintenance of the unit. 

2.2.0 Areas of use 

Window models are designed for comfort ventilation for institutions, canteens, offices and 
conference rooms etc. 

2.3.0 Incorrect use 

The  window  models  are  not  designed for  local  exhaust  ventilation,  and  are  therefore  not 
suitable for this purpose. 

2.4.0 Scope of delivery 

TX window models are supplied with the following main components: 
 
1. Turbovex TX window model  
2. TX electronic controller 

 
    Figure 1 Deliverables 

 

 

 
 

Содержание TX 350A

Страница 1: ...1 of 23 Turbovex A S Industrivej 45 DK 9600 Aars Tel 45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk Installation operation and maintenance guide for window models Rev 2014 0...

Страница 2: ...0 0 INSTALLATION OF UNIT 6 3 1 0 EXTERNAL DIMENSIONS 6 3 2 0 WALL WINDOW INSTALLATION 7 4 0 0 PLACING THE UNIT 11 PLACING THE UNIT CONT 12 5 0 0 SERVICE 13 5 1 0 FILTER CHANGE 13 5 2 0 REMOVING FILTER...

Страница 3: ...ins technical information and details of installation and maintenance of the unit 2 2 0 Areas of use Window models are designed for comfort ventilation for institutions canteens offices and conference...

Страница 4: ...info turbovex dk www turbovex dk 2 5 0 Main components Figure 2 Main components 1 Intake Air 2 Exhaust Air 3 Extract Air 4 Supply Air 5 Counterflow heat exchanger 6 Supply Air Fan 7 Extract Air Fan 8...

Страница 5: ...Page 5 of 23 Turbovex A S Industrivej 45 DK 9600 Aars Tel 45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk Figure 3 Main components 1 2 7...

Страница 6: ...urbovex dk 3 0 0 Installation of unit 3 1 0 External dimensions Intake zone Minimum required distance to walls floor and ceiling is 70 mm Dimensions mm TX350A A Height 1400 B Width 662 C Depth 334 D M...

Страница 7: ...ail info turbovex dk www turbovex dk 3 2 0 Wall window installation Internal reinforcement is built into the sides within the marked areas Holes can be drilled in these areas as required for installat...

Страница 8: ...Page 8 of 23 Turbovex A S Industrivej 45 DK 9600 Aars Tel 45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk Plane cross section for window wall...

Страница 9: ...Page 9 of 23 Turbovex A S Industrivej 45 DK 9600 Aars Tel 45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk Vertical cross section upper part...

Страница 10: ...Page 10 of 23 Turbovex A S Industrivej 45 DK 9600 Aars Tel 45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk Vertical cross section lower part...

Страница 11: ...0 Placing the unit The unit is usually placed in the wall by a window This position makes the most of the coanda effect which circulates fresh air well into the room This gives the air longer to mix w...

Страница 12: ...45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk Placing the unit cont Place the unit with the edge of the cabinet flush with the inside of the wall in the room Ensure free ai...

Страница 13: ...96 42 24 e mail info turbovex dk www turbovex dk 5 0 0 Service 5 1 0 Filter change We recommend changing the filters and carefully cleaning the exchanger 2 4 times a year Upper keyhole Lower keyhole...

Страница 14: ...Page 14 of 23 Turbovex A S Industrivej 45 DK 9600 Aars Tel 45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk 5 2 0 Removing filters and exchanger...

Страница 15: ...of 23 Turbovex A S Industrivej 45 DK 9600 Aars Tel 45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk Change upper filter with inner door open Change lower filter with inner doo...

Страница 16: ...DK 9600 Aars Tel 45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk Remove inner door and filters to be able to lift out the heat exchanger Clean heat exchanger carefully using...

Страница 17: ...o turbovex dk www turbovex dk 6 0 0 Connecting mains electricity 6 1 0 Connection Cable grommet holes Terminal clamps for connecting mains electricity Note Connection of mains electricity must be perf...

Страница 18: ...ge 18 of 23 Turbovex A S Industrivej 45 DK 9600 Aars Tel 45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk 6 2 0 Wiring diagram Connect Turbovex unit according to wiring diagra...

Страница 19: ...urban traffic approx 90 dB A Temperature efficiency degree at the heat exchanger is stated in and is the relationship between the temperature differences achieved and the maximum achievable temperatur...

Страница 20: ...Aars Tel 45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk 7 1 0 Sound test Sound test performed in our laboratory on 12 10 11 Principle Sketch Result 30 dB 290m h consumption...

Страница 21: ...through the fan blade out through the louvres in the top and in to the room The extract air fan 4 draws air from the room through the louvres in the bottom and sides up through the filter 5 through t...

Страница 22: ...d is set on the control panel We recommend that the temperature should not be set higher than the room temperature Fresh air temperature should be 2 3 degrees below room temperature to achieve the bes...

Страница 23: ...fety of Machines Basic concepts general principles for design Part 1 Basic terminology and methodology ISO 12100 1 2003 DS EN 12100 2 A1 2009 Safety of Machines Basic concepts general principles for d...

Отзывы: