![Turbosol POLI T Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/turbosol/poli-t/poli-t_instructions-for-use-and-maintenance-manual_1181320023.webp)
22
23
The tightness of the clamp being equal, the pump exerts
a considerably higher pressure on the material than on
the water. Tighten the clamp until an adequate pressure
is obtained.
At the end put the clamp back to the previous normal
working position.
Should the hose still not be clean, repeat the operation.
Never direct the water jet towards the switchboard
or the electric motors when washing the machine.
Never direct the water jet at persons.
Use suitable protective gear, in particular for the
hands and eyes.
Before stopping the machine:
• Stop the mortar pump using the start/stop button
I/0
(32)
, the pan mixer by putting the on/off switch to
0 (41)
and the compressor using button
(53)
.
Now switch off the machine
using the on/off switch
(35)
located on the control panel.
Should an
EMERGENCY
STOP
be necessary, put the red
on/off switch with yellow background
(35)
, located
on the machine control panel, to
0
.
To avoid overloading and the consequent
early wear of the pumping equipment, stop
the machine with the variator flywheel in the
centre position WHEN YOU HAVE FINISHED
WORKING. (In this way, when the machine
is started the next time, the variator has a
higher torque and the risk of slippage is
therefore reduced).
53
35
Содержание POLI T