- Start the mortar pump by pressing the relative start/
stop button
I/0 (32)
.
- Read the pumping pressure shown on the pressure
gauge installed on the mortar delivery header
(33).
The values should be approximately those given in
the table.
- After a few seconds (approx. 10 seconds), stop the
pump: the pump holding pressure can be read on the
pressure gauge and should be equivalent to approx.
half the pumping pressure measured previously.
•
Calibrating the pump
If a new pump has been installed and in any case every
day prior to commencing work with the material, it is
advisable to check pump calibration as follows:
- Mount the pump
calibrating unit
(29)
, with the
shutoff valve
open.
- Fill the hopper with
water.
- Open the air control valve
(14)
located on the gun and the air
supply valve
(30)
to be found
on the machine.
- Close the shutoff valve
(31)
of the pump calibrating
unit.