Starting
Close the air supply valve
(30)
located on the machine and
open the air control valve
on the gun
(14)
.
Fill the hopper with water to prevent the screw from
working dry.
Put the on/off switch
(35)
to the position
I
and the reversing
gear
(36)
to position
1
or
2
.
The white indicator light
(37)
indicating power comes on.
Start the mortar pump by pressing the start/stop button
I/0 (32)
.
The pump starts
to turn; check the
correct direction
of rotation of the
screw
(38)
and if
necessary invert
the position of the
reversing gear
(36)
.
The red indicator light
(39)
comes on when the
hopper safety grid is open. The agitator stops when
the red indicator light is on.
The red indicator light also comes on should the
overload cutout trip.
Check that the safety grid is in proper working order: upon
lifting it, pumping stops and the red indicator light
(39)
on
the switchboard comes on.
To start the machine again, press the start/stop button
(32)
. With the mortar pump in operation, adjust the pump
output.
The output may only be adjusted with the
pump in operation, otherwise the variable-
speed drive could be seriously damaged.
When reversing the pump direction of rotation
due to plugging of the hoses, first stop the pan
mixer (/MP version).
Start the compressor by pressing
the green button
(40)
located on
the pressure switch.
Check correct operation of the whole assembly.
30
32
36
37
35
39
38
40
14
Содержание POLI T
Страница 31: ...31 ...