background image

4

Installation Instructions: 
The TurboChef 30

˝

 Double wall speedcook oven

specs & Dimensions

DIMensIons

Overall Oven

Height 

50.25˝ 

(127.6)

Width 

30.00˝ 

(76.2)

Depth 

23.90˝ 

(60.7)

Depth from Wall 

4.25˝ 

(10.8)

  with top door open

 

17.50˝

 

(44.5

)

 

with 

bottom door open

 

19.50˝ 

(49.5)

Weight 

410 lbs. 

(186 kg.)

Top Oven Cavity

Height 

12.00˝ 

(30.5)

Width 

24.00˝ 

(61.0)

Depth  

15.00˝ 

(38.1)

Cooking Space 

2.5 cubic feet

Bottom Oven Cavity

 

Height 

15.50 

(39.4)

Width 

24.00˝ 

(61.0)

Depth 

17.50˝ 

(44.5)

Cooking Space 

3.77 cubic feet

Cabinet

Width (minimum) 

30.00˝ 

(76.2)

Rough Wall Opening

 

Height (min/max) 

48.875˝ 

(124.1)

 

Width (min/max) 

28.50˝ 

(72.6)

 

Depth (minimum) 

24.00˝ 

(61.0)

Thickness (minimum) 

0.375˝ 

(0.9)

Cabinet Base Height
  Minimum/Maximum 

8.0˝/ 15.0˝ 

(20.3 / 38.1)

  Recommended 

11.0˝ 

(27.9)

Dimensions in parentheses are in centimeters unless otherwise noted.

Due to the depth of the oven frame (23.9˝(60.7 cm)), the power supply 
line location shown in the illustrations on page 5 (high or low conduit 
box) must be adhered to in order to obtain a proper fit in the cabinet.

Specifications are subject to change without notice. 

eleCTrICal speCIfICaTIons

Electrical Supply Requirements:

Single Phase, 208 VAC, 60 Hz, 50 Amps, 4-wire 
Model: TDO30 * 208
Single Phase, 240 VAC, 60 Hz, 50 Amps, 4-wire 
Model: TDO30 * 240
“*” 

Indicates a two letter code – OR, RD, BU, CH, IV, WH, or SS – 

which refers to the oven door color.

Connection:

 

Unit includes a 5½ foot flex conduit to be used 

between the oven and conduit box. Connectors are supplied by 
installation electrician.

Total Connected Power:

 50 Amps 

Branch circuits must be protected with a 50 Amp  
over-current protector.

InCluDeD aCCessorIes

1 oven rack for top Speedcook oven
2 oven racks (1 standard/1 roller rack) for bottom oven
Meat probe for the bottom oven
TurboChef Cookbook

proper CabIneT preparaTIon

Cabinets should be cut according to supplied dimension. If the 
oven is being installed near a wall or door, there should be at least 
∑-inch space between the wall/door and the side of the oven door.

TurboChef recommends using standard 2 x 4 support posts with  
a minimum of ∆-inch solid base to support the oven. Support 
posts should be level with the floor line and well-secured to the 
base of the cabinet. Base cabinet support must be able to support 
the oven’s weight (410 lbs.). TurboChef strongly recommends a 
solid base as shown in the illustrations in Figure 6.

If necessary due to a low or high conduit box, a 2-inch  diameter 
hole should be drilled in the appropriate area to allow the power 
cord to reach the power source. Refer to Figure 6.

The oven utilizes ambient air from the kitchen – which is drawn  
in through the top control panel area via openings in the top 
access panel – to assist in keeping operational components cool. 
Please allow a 1-inch minimum clearance for any cabinet doors 
above this area.

Should you have any questions or concerns about how the  
cabinets are built, please contact TurboChef Customer Service 

866.44serve (866.447.3783) 

before installing the oven.

Содержание TD030* 208

Страница 1: ...properly Remove each support rail by unscrewing the support screw on either side of the rail Supports should then slide off the oven base screw hole locations figure 3 The oven must be secured to the...

Страница 2: ...mplete Instructions o 1 Ensure power is disconnected at the breaker o 2 Remove oven from box crate and place on a level surface NOTE The oven is shipped with two 2 support rails attached to the bottom...

Страница 3: ...engage the inner cabinet and secure the oven in place See Figure 3 on page 1 o 9 Reconnect power to the breaker o 10 Remove all wire ties from the top and bottom oven cavities o 11 Verify the oven is...

Страница 4: ...be used between the oven and conduit box Connectors are supplied by installation electrician Total Connected Power 50 Amps Branch circuits must be protected with a 50 Amp over current protector Includ...

Страница 5: ...c Zki ZXc flkc k j cfn Kf fYkX e gifg i k f k_ fm e ekf k_ ZXY e kj aleZk fe Yfo dljk Y cfZXk XYfm fi Y cfn k_ fm e fg e e Kf fYkX e gifg i k f k_ fm e ekf k_ ZXY e kj aleZk fe Yfo dljk Y cfZXk XYfm...

Страница 6: ......

Страница 7: ...a apropiadamente Quite cada carril de apoyo desatornillando el tornillo de apoyo a ambos lados del carril Los apoyos deber n deslizarse entonces de la base de horno Posiciones de Agujeros para Tornill...

Страница 8: ...de ste Estos carriles permiten que el horno se siente al nivel y mantenga el fondo del marco fuera de da os durante la instalaci n Para colocar correctamente el horno en los gabinetes estos carriles d...

Страница 9: ...rificado regrese CookWheel a la posici n de Apagado Off NotA NO intente establecer algunas programaciones de cocina en el horno superior durante la instalaci n El retiro de literatura y operaci n del...

Страница 10: ...aja de conducto y el horno Los conecto res son suministrados por el electricista de instalaci n Poder Conectado Total 50 Amperios Accesorios Incluidos 1 parilla para el horno superior Speedcook 2 esta...

Страница 11: ...kfdX c Zki ZX j YXaX GXiX fYk e i leX ZfcfZXZ e Xgifg X X c _fief e cfj XY e k j c eZ_l Y cfZXc qXij eZ dX f YXaf cX Xg ikliX c _fief GXiX fYk e i leX ZfcfZXZ e Xgifg X X c _fief e cfj XY e k j c eZ_...

Страница 12: ...om Customer Service 866 44serve Sales Marketing 866 54enjoy Installation Instructions The TurboChef 30 Double Wall SpeedCook Oven Retain these instructions for use by an Electrical Inspector and for f...

Отзывы: