1. Scope  

 

This document describes the basic operation of the Turbo Energy brand lithium-
ion  rechargeable  battery  (

Lithium  Series  48V  2.4  kWh  model

).  This  manual 

contains  all  the  necessary  details  for  understanding  the  operation  of  the 
equipment and for its correct application. 

 

2. Specifications   

 

 

 

 

 

 

Electrical

 

 

 

Nominal Energy

 

2.4 kWh

 

Nominal Capacity

 

50Ah

 

Depth of Discharge (DoD)

 

90%

 

Nominal Voltage

 

48V

 

Voltage operating range

 

40.5 - 54V

 

Cycle Life

 

>= 6000

 

Physical

 

 

 

Weight

 

22 kg

 

Dimensions

 

480 x 360 x 90 mm

 

Protection class

 

IP20

 

Battery type

 

LiFePO

4

 

Operation

 

 

 

Charge/discharge current

 

25A (0.5 C)

 

Max. Charge current 

 

45A

 

Max. Discharge current

 

55A

 

Temperature operating range (charge)

 

0ºC…50ºC

 

Temperature operating range (discharge)

 

-

20ºC…50ºC

 

Humidity

 

5%...85%

 

Max. operating altitude

 

< 4000 m

 

BMS

 

 

 

Monitoring parameters

 

System voltage, Cell voltaje, 
current and temperature

 

Communication

 

Compatible CAN and RS-485

 

Содержание Lithium 48V 2.4 kWh

Страница 1: ...https www turbo e com Instruction Manual Lithium Series 48V 2 4 kWh Battery...

Страница 2: ...tection 7 4 2 4 Other Protection 7 4 3 DIP switch 7 4 4 Assembly and connection 9 4 4 1 Components list 9 4 4 2 Mechanical instalation 10 4 4 3 Electrical installation 11 4 5 Battery parameter setting...

Страница 3: ...50Ah Depth of Discharge DoD 90 Nominal Voltage 48V Voltage operating range 40 5 54V Cycle Life 6000 Physical Weight 22 kg Dimensions 480 x 360 x 90 mm Protection class IP20 Battery type LiFePO4 Operat...

Страница 4: ...y can be expanded by incorporating more batteries 4 Operation 4 1 Battery front Item Name Definition 1 Power switch OFF ON must be in the ON state when in use 2 Ground connection point Shell ground co...

Страница 5: ...t support CAN RS485 communication factory default CAN communication 10 DRY CONTACT 11 ADD DIP switch Battery Status SOC LED1 LED2 LED3 LED4 ALM RUN Shutdown off off off off off off Standby 75 SOC 100...

Страница 6: ...ops charging when total voltage or any battery cell voltage reaches the rated protection value during charging stage When total voltage or all cell back to rated range the protection is over 4 2 2 Cur...

Страница 7: ...rom the shutdown state if a short circuit occurs the system starts short circuit protection for 60 seconds Self Shutdown When device connects no external loads and power supply and no external communi...

Страница 8: ...DELIOS GROWATT HVM Master Slaves Inverter VOLTRONIC Axpert VMIII Axpert King Growatt SPH SPA Master Slaves Inverter GROWATT SPH SPA Master Slaves Inverter GROWATT SPF HVM Master Slaves 3 If the energ...

Страница 9: ...Figure Battery B4850 48V 50Ah 480 360 90mm 1 Power cable positive Red 25mm2 L2050m m 1 Power cable negative Black 25mm2 L2050m m 1 Parallel cable positive Red 25mm2 L215mm 1 Parallel cable negative Bl...

Страница 10: ...er Manual LIS 24 User manual 1 1 Place the Lithium Series 48V 2 4 kWh unit on the rack bracket as shown in the figure and push the device into the cabin at the installation position The cabinet struct...

Страница 11: ...ole if the resistor shows infinity means that the cable is available After visual testing of power line is connection the positive and negative poles of the battery shall be connected respectively to...

Страница 12: ...figure Important Connect the specific communication cable supplied by the provider Connect the communication cable between batteries Negative power cable Positive power cable Positive parallel cable...

Страница 13: ...ettings Max Charging Bulk Voltage 53 5V Absorption Voltage 53V Float Voltage 52 5V Shut Down cut off Voltage 47V Shut Down cut off SOC 20 Restart Voltage 49V Max Charge Current 25A battery QTY Max Dis...

Страница 14: ...the circuit breaker battery input terminal has a voltage output and is greater than 42V then the battery begun to work normally 4 After confirming that the battery output voltage and polarity are corr...

Страница 15: ...r current RED Buzzer start Stop charging and find out the cause of the trouble High temp RED Stop charging Discharge state Over current RED Buzzer start Stop discharging and find out the cause of the...

Страница 16: ...lacement or add more modules 4 The battery cannot be fully charged to 100 Charging voltage is too low Adjust charging voltage at 53 5V or 54V 5 The power cable sparks once power on and ALM light RED P...

Страница 17: ...y place 9 Never expose the battery to fire or water 6 2 Safety warnings 1 Do not disassemble the batteries The inside of the battery has a protective mechanism and a protective circuit to avoid danger...

Страница 18: ...completely It can be harmful to the skin and if you touch the eyes wash and go to the hospital immediately for treatment 6 3 Environmental protection Turbo Energy s batteries comply with EU ROHS regu...

Отзывы: