background image

 

13 

 

After the whole system connection, set the master DIP mode according to the 
inverter model firstly, then start the battery. 

The BAT-INV comms cable is from inverter comm port to master CAN IN port, BAT-
BAT cable is from master CAN OUT to slave1 CAN IN, slave1 CAN OUT to slave2 

CAN IN…

 

Each pair of power cable, it is limited continuous current is 120A, so if the inverter 
Max. work current more than 120A, please add power cable according to the 
proportion. 

 

4.5.  Battery parameter settings on the inverter 

 

The following parameters must be set into inverter settings: 

 

Max Charging (Bulk) Voltage: 53.5V 

 

Absorption Voltage: 53V 

 

Float Voltage: 52.5V 

 

Shut Down (cut off) Voltage: 47V 

 

Shut Down (cut off) SOC: 20% 

 

Restart Voltage: 49V 

 

Max Charge Current: 25A*battery QTY 

 

Max Discharge Current: 25A * battery QTY 

 

Capacity: 50Ah* battery QTY 

 

5. Use, maintenance and problem solving 

 

5.1.  Commissioning and use of the equipment 

 

After completing the electrical installation, follow these steps to start the battery 
system: 

1.

 

Refer to the description of the DIP switch of 4.2. to prepare the battery 
module before starting up, then press the ON/OFF button to the ON 
position, next press and hold the SW button for 3 seconds.  

 

2.

 

After  the  indicator  self-test,  the  RUN  indicator  will  light  and  the  SOC 
indicator will be on (100% SOC status in the figure)

 

 

Содержание Lithium 48V 2.4 kWh

Страница 1: ...https www turbo e com Instruction Manual Lithium Series 48V 2 4 kWh Battery...

Страница 2: ...tection 7 4 2 4 Other Protection 7 4 3 DIP switch 7 4 4 Assembly and connection 9 4 4 1 Components list 9 4 4 2 Mechanical instalation 10 4 4 3 Electrical installation 11 4 5 Battery parameter setting...

Страница 3: ...50Ah Depth of Discharge DoD 90 Nominal Voltage 48V Voltage operating range 40 5 54V Cycle Life 6000 Physical Weight 22 kg Dimensions 480 x 360 x 90 mm Protection class IP20 Battery type LiFePO4 Operat...

Страница 4: ...y can be expanded by incorporating more batteries 4 Operation 4 1 Battery front Item Name Definition 1 Power switch OFF ON must be in the ON state when in use 2 Ground connection point Shell ground co...

Страница 5: ...t support CAN RS485 communication factory default CAN communication 10 DRY CONTACT 11 ADD DIP switch Battery Status SOC LED1 LED2 LED3 LED4 ALM RUN Shutdown off off off off off off Standby 75 SOC 100...

Страница 6: ...ops charging when total voltage or any battery cell voltage reaches the rated protection value during charging stage When total voltage or all cell back to rated range the protection is over 4 2 2 Cur...

Страница 7: ...rom the shutdown state if a short circuit occurs the system starts short circuit protection for 60 seconds Self Shutdown When device connects no external loads and power supply and no external communi...

Страница 8: ...DELIOS GROWATT HVM Master Slaves Inverter VOLTRONIC Axpert VMIII Axpert King Growatt SPH SPA Master Slaves Inverter GROWATT SPH SPA Master Slaves Inverter GROWATT SPF HVM Master Slaves 3 If the energ...

Страница 9: ...Figure Battery B4850 48V 50Ah 480 360 90mm 1 Power cable positive Red 25mm2 L2050m m 1 Power cable negative Black 25mm2 L2050m m 1 Parallel cable positive Red 25mm2 L215mm 1 Parallel cable negative Bl...

Страница 10: ...er Manual LIS 24 User manual 1 1 Place the Lithium Series 48V 2 4 kWh unit on the rack bracket as shown in the figure and push the device into the cabin at the installation position The cabinet struct...

Страница 11: ...ole if the resistor shows infinity means that the cable is available After visual testing of power line is connection the positive and negative poles of the battery shall be connected respectively to...

Страница 12: ...figure Important Connect the specific communication cable supplied by the provider Connect the communication cable between batteries Negative power cable Positive power cable Positive parallel cable...

Страница 13: ...ettings Max Charging Bulk Voltage 53 5V Absorption Voltage 53V Float Voltage 52 5V Shut Down cut off Voltage 47V Shut Down cut off SOC 20 Restart Voltage 49V Max Charge Current 25A battery QTY Max Dis...

Страница 14: ...the circuit breaker battery input terminal has a voltage output and is greater than 42V then the battery begun to work normally 4 After confirming that the battery output voltage and polarity are corr...

Страница 15: ...r current RED Buzzer start Stop charging and find out the cause of the trouble High temp RED Stop charging Discharge state Over current RED Buzzer start Stop discharging and find out the cause of the...

Страница 16: ...lacement or add more modules 4 The battery cannot be fully charged to 100 Charging voltage is too low Adjust charging voltage at 53 5V or 54V 5 The power cable sparks once power on and ALM light RED P...

Страница 17: ...y place 9 Never expose the battery to fire or water 6 2 Safety warnings 1 Do not disassemble the batteries The inside of the battery has a protective mechanism and a protective circuit to avoid danger...

Страница 18: ...completely It can be harmful to the skin and if you touch the eyes wash and go to the hospital immediately for treatment 6 3 Environmental protection Turbo Energy s batteries comply with EU ROHS regu...