background image

 

17 

 

6.

 

Appendix 

 

6.1.

 

Safety instructions 

 

1.

 

Please read the battery instructions before use. 

2.

 

Keep the battery away from high voltage and out of reach of children. 

3.

 

In  operation,  the  battery  should  be  kept  in  the  set  temperature  ranges 
(between -20ºC and 50ºC) and a humidity less than 85%. 

4.

 

During handling, be very careful to avoid bumps/falls of the battery. 

5.

 

Be careful not to touch the contacts at the same time. 

6.

 

The battery, at the end of its useful life, requires a recovery process, not 
disassemble it. 

7.

 

Avoid locating batteries in damp places to avoid danger. 

8.

 

When not in use for a long time, store the battery intact and let the battery 
be half charged. Wrap the battery with non-conductive material to avoid 
direct contact of the metal. Store the battery in a cool, dry place. 

9.

 

Never expose the battery to fire or water. 

 

6.2.

 

Safety warnings 

 

1.

 

Do not disassemble the batteries. The inside of the battery has a protective 
mechanism  and  a  protective  circuit  to  avoid  danger.  Improper 
disassembly  will  damage  the  protection  function  permanently,  leaving 
the battery without safety conditions. 

2.

 

Never short-circuit the poles of the battery. Avoid contact of positive and 
negative poles with metals. 

3.

 

Keep the batteries away from fire and extreme temperatures. Monitor the 
distance to thermal bulbs, stoves, etc. 

4.

 

Keep the battery away from the water. Always be careful that the battery 
is not located in damp places where the dew point can be reached. 

5.

 

Do not use batteries that have physical damage that may be due to falls 
or bumps. 

6.

 

Do not weld near the battery. 

7.

 

Overheating will result in the loss of the protective function of its life cycle, 
even, it could render the battery useless and in extreme cases self-ignition 
of the battery occurs. 

Содержание Lithium 48V 2.4 kWh

Страница 1: ...https www turbo e com Instruction Manual Lithium Series 48V 2 4 kWh Battery...

Страница 2: ...tection 7 4 2 4 Other Protection 7 4 3 DIP switch 7 4 4 Assembly and connection 9 4 4 1 Components list 9 4 4 2 Mechanical instalation 10 4 4 3 Electrical installation 11 4 5 Battery parameter setting...

Страница 3: ...50Ah Depth of Discharge DoD 90 Nominal Voltage 48V Voltage operating range 40 5 54V Cycle Life 6000 Physical Weight 22 kg Dimensions 480 x 360 x 90 mm Protection class IP20 Battery type LiFePO4 Operat...

Страница 4: ...y can be expanded by incorporating more batteries 4 Operation 4 1 Battery front Item Name Definition 1 Power switch OFF ON must be in the ON state when in use 2 Ground connection point Shell ground co...

Страница 5: ...t support CAN RS485 communication factory default CAN communication 10 DRY CONTACT 11 ADD DIP switch Battery Status SOC LED1 LED2 LED3 LED4 ALM RUN Shutdown off off off off off off Standby 75 SOC 100...

Страница 6: ...ops charging when total voltage or any battery cell voltage reaches the rated protection value during charging stage When total voltage or all cell back to rated range the protection is over 4 2 2 Cur...

Страница 7: ...rom the shutdown state if a short circuit occurs the system starts short circuit protection for 60 seconds Self Shutdown When device connects no external loads and power supply and no external communi...

Страница 8: ...DELIOS GROWATT HVM Master Slaves Inverter VOLTRONIC Axpert VMIII Axpert King Growatt SPH SPA Master Slaves Inverter GROWATT SPH SPA Master Slaves Inverter GROWATT SPF HVM Master Slaves 3 If the energ...

Страница 9: ...Figure Battery B4850 48V 50Ah 480 360 90mm 1 Power cable positive Red 25mm2 L2050m m 1 Power cable negative Black 25mm2 L2050m m 1 Parallel cable positive Red 25mm2 L215mm 1 Parallel cable negative Bl...

Страница 10: ...er Manual LIS 24 User manual 1 1 Place the Lithium Series 48V 2 4 kWh unit on the rack bracket as shown in the figure and push the device into the cabin at the installation position The cabinet struct...

Страница 11: ...ole if the resistor shows infinity means that the cable is available After visual testing of power line is connection the positive and negative poles of the battery shall be connected respectively to...

Страница 12: ...figure Important Connect the specific communication cable supplied by the provider Connect the communication cable between batteries Negative power cable Positive power cable Positive parallel cable...

Страница 13: ...ettings Max Charging Bulk Voltage 53 5V Absorption Voltage 53V Float Voltage 52 5V Shut Down cut off Voltage 47V Shut Down cut off SOC 20 Restart Voltage 49V Max Charge Current 25A battery QTY Max Dis...

Страница 14: ...the circuit breaker battery input terminal has a voltage output and is greater than 42V then the battery begun to work normally 4 After confirming that the battery output voltage and polarity are corr...

Страница 15: ...r current RED Buzzer start Stop charging and find out the cause of the trouble High temp RED Stop charging Discharge state Over current RED Buzzer start Stop discharging and find out the cause of the...

Страница 16: ...lacement or add more modules 4 The battery cannot be fully charged to 100 Charging voltage is too low Adjust charging voltage at 53 5V or 54V 5 The power cable sparks once power on and ALM light RED P...

Страница 17: ...y place 9 Never expose the battery to fire or water 6 2 Safety warnings 1 Do not disassemble the batteries The inside of the battery has a protective mechanism and a protective circuit to avoid danger...

Страница 18: ...completely It can be harmful to the skin and if you touch the eyes wash and go to the hospital immediately for treatment 6 3 Environmental protection Turbo Energy s batteries comply with EU ROHS regu...

Отзывы: