FSL-0019.DOCX
Page 8 of 14
Rev. 4
equivalent load measuring device. This test load shall be the maximum rating of
the hoist for the specific application (at the normal relief valve setting for the hoist) -
NOT the reduced rating used for personnel lifts.
2. The hoist must be dynamically tested by rotating the drum several times, in both
the hoisting and lowering directions, while under a load of at least 30% of the hoist
lifting capacity. Check for smooth operation during this procedure.
3. The hoist internal friction brake shall be tested per the procedures in section 3.0 of
this manual.
4. After inspection or rebuild and testing, a new certificate for personnel handling shall
be issued by the inspector / service technician, effective on the date the hoist is
placed back in service. A sample certificate is shown below, and shall include, at a
minimum, all of the information depicted here.
Name of Service Company
Approved by TULSA WINCH for handling personnel if used and maintained in accordance
with TULSA WINCH Recommendations For Personnel Handling Hoists
Hoist Model No.:___________________________________
Hoist Serial No.: ___________________________________
Date of Inspection: _________________________________
Work Order/Job No: ________________________________
Inspector's Name: _________________________________
For a copy of recommendations call or write: TULSA WINCH
11135 S. James Ave, Jenks, OK, 74037, USA (918) 298-8300
Содержание API