C.  Night Pause Time (hold open time related to Night Switch) 

I.  Adjustable 0 to 30 seconds (default is 7 seconds) 

D.  Obstacle Detection 

I.  Standard– 3 opening attempts are made following an obstacle detection.  The door will close fully without reacti-

vation capability.  Once fully closed, activation will be allowed after the control resets itself. 

II.  Non-Standard– 3 opening attempts are made following an obstacle detection.  The door must then be moved to 

the closed position manually. 

B.  Cycle Count 

I.  Shows the number of door cycles. 

II.  Count is non-resettable. 

III.  Cycles are counted only when TAP control is connected. 

5.  ADVANCED MENU 

A.  Password-Password-Password 

B.  Operation Parameters 

I.  Closing Speed 

A.  Adjustable 0-30 seconds (Default is 8). 

II.  Opening Speed 

A.  Adjustable 0-30 seconds (Default is 8). 

III. Keep Settings 

A.  On= Settings are kept once the TAP is disconnected 

B.  Off= Settings are not kept once the TAP is disconnected.  Speed and time settings are then adjusted by 

control trimmers. 

3.  LOCK 

A.  Kit Lock 

I.  On= Lock installed 

A.  Night:  The door is locked when On/Off switch is OFF. 

B.  One-Way + Night:  The door is locked when the On/Off switch is in the Night or One-Way position. 

C.  Always: Door is locked whenever it is closed. 

II.  Off= No lock installed. 

4.  DIAGNOSTICS 

A.  Version 

III. 2 Leaves (Pairs) 

A.  Off:  No controls linked to each other. 

B.  On:  2 controls are tied together:  Terminals 26 to 26 and 28 to 28. 

C.  Master:  Begins to open first. 

D.  Slave:  Begins to open second. 

IV.  Exit 

C.  In/Out Setup 

I.  Emergency 

A.  Open: Triggering this command causes the door to open. 

B.  Close: Triggering this command causes the door to close. 

C.  NO: Normally open input. 

D.  NC: Normally closed input. 

II.  Out Op/CI 

A.  NO: Normally open door status switch. 

B.  NC: Normally closed door status switch. 

III.  Out Alarm 

A.  NO: Sets the output alarm status to normally open. 

D.  Various 

I.  Standard Setup 

A.  Standard:  An asterisk (*) is shown when selected. 

B.  Non-Standard:  An asterisk (*) is shown when selected. 

II.  Interlock 

A.  Off:  Interlock function is inactive. 

B.  On:  Interlock function is active.  The opening of one door is dependent upon the 2nd door being 

closed 

C.  Master:  Sets the current control to be the Master 

D.  Slave:  Sets the current control to be the Slave 

Содержание TAP

Страница 1: ...all dress plate E into the programmer module D Upon powering on the display on the TAP control will show a date time and the red LED s will illuminate to indicate current function positions The function of the door can be altered by pressing the desired button Pressing a button more than once toggles between functions for that button i e button number 4 can be used to command a door opening for te...

Страница 2: ...3 LOCK A Kit Lock I On Lock installed A Night The door is locked when On Off switch is OFF B One Way Night The door is locked when the On Off switch is in the Night or One Way position C Always Door is locked whenever it is closed II Off No lock installed 4 DIAGNOSTICS A Version III 2 Leaves Pairs A Off No controls linked to each other B On 2 controls are tied together Terminals 26 to 26 and 28 to...

Страница 3: ...ress OK 13 Select ON 14 Press OK 15 Press Down until EXIT displays 16 Press OK PROGRAMMING EXAMPLE Set OPENING SPEED to a value of 5 and choose to KEEP SETTINGS 1 Press the down arrow until ADVANCED MENU appears in the display 2 Press OK 5 times to scroll past setting the PASSCODE default is 000 3 OPERATION appears in the display 4 Press OK 5 CLOSING SPEED displays 6 Press Down arrow until OPENING...

Страница 4: ...iation of Automatic Door manufacturers AAADM This inspection must be performed by a certified AAADM trained inspector Tucker recommends this documented inspection be performed upon completion of the installation as well as following the completion of every service call thereafter If service is not performed within one year of the previous service action a routine AAADM inspection should be perform...

Отзывы: