Universal Key-Pad
TAP
C. Night Pause Time (hold open time related to Night Switch)
I. Adjustable 0 to 30 seconds (default is 7 seconds)
D. Obstacle Detection
I. Standard– 3 opening attempts are made following an obstacle detection. The door will close fully without reacti-
vation capability. Once fully closed, activation will be allowed after the control resets itself.
II. Non-Standard– 3 opening attempts are made following an obstacle detection. The door must then be moved to
the closed position manually.
B. Cycle Count
I. Shows the number of door cycles.
II. Count is non-resettable.
III. Cycles are counted only when TAP control is connected.
5. ADVANCED MENU
A. Password-Password-Password
B. Operation Parameters
I. Closing Speed
A. Adjustable 0-30 seconds (Default is 8).
II. Opening Speed
A. Adjustable 0-30 seconds (Default is 8).
III. Keep Settings
A. On= Settings are kept once the TAP is disconnected
B. Off= Settings are not kept once the TAP is disconnected. Speed and time settings are then adjusted by
control trimmers.
3. LOCK
A. Kit Lock
I. On= Lock installed
A. Night: The door is locked when On/Off switch is OFF.
B. One-Way + Night: The door is locked when the On/Off switch is in the Night or One-Way position.
C. Always: Door is locked whenever it is closed.
II. Off= No lock installed.
4. DIAGNOSTICS
A. Version
III. 2 Leaves (Pairs)
A. Off: No controls linked to each other.
B. On: 2 controls are tied together: Terminals 26 to 26 and 28 to 28.
C. Master: Begins to open first.
D. Slave: Begins to open second.
IV. Exit
C. In/Out Setup
I. Emergency
A. Open: Triggering this command causes the door to open.
B. Close: Triggering this command causes the door to close.
C. NO: Normally open input.
D. NC: Normally closed input.
II. Out Op/CI
A. NO: Normally open door status switch.
B. NC: Normally closed door status switch.
III. Out Alarm
A. NO: Sets the output alarm status to normally open.
D. Various
I. Standard Setup
A. Standard: An asterisk (*) is shown when selected.
B. Non-Standard: An asterisk (*) is shown when selected.
II. Interlock
A. Off: Interlock function is inactive.
B. On: Interlock function is active. The opening of one door is dependent upon the 2nd door being
closed
C. Master: Sets the current control to be the Master
D. Slave: Sets the current control to be the Slave
3
4