background image

Universal Key-Pad 

TAP  

SELECT ALL DAYS AND SET THE FOLLOWING 

Time Band 1 

Function 1 

08:00 pm 

Time Band 2 

Function 2 

06:00 pm 

Time Band 3 

Function 8 

07:00 pm 

Time Band 4 

Function 0 

  

Time Band 5 

Function 0 

  

SELECT SATURDAY AND SET THE FOLLOWING 

Time Band 1 

Function 8 

Time Band 2 

Function 8 

Time Band 3 

Function 8 

Time Band 4 

Function 0 

Time Band 5 

Function 0 

Select SUNDAY and repeat settings 

D.  Time band starting time:  Set the activation time for the time band.  It is not necessary to enter in chronological 

order. 

*EXAMPLE 

Program the unit to function as follows: 

MONDAY through FRIDAY 

 

Start at 8am for Automatic Bi-Directional Full Opening 

 

Start at 6pm for Automatic 1-Way Full Opening 

 

Start at 7pm for Night Function 

SATURDAY and SUNDAY 

 

Set to Night Function for the whole weekend 

Tucker Auto-Mation, LLC (hereafter referred  to as  “Tucker”) recommends that all of its automated  pedestrian  door 
products be installed by a trained automatic door technician and that the resulting performance of the product be in 
full  compliance  with  the  most  current  version  of  the  American  National  Standards  Institute  document  A156.10  or 
A156.19 (whichever is applicable) as  well  as any applicable  building codes and/or fire codes. Tucker further recom-
mends that a full inspection of the operating system be performed in accordance with the guidelines of the American 
Association  of  Automatic  Door  manufacturers  (AAADM).  This  inspection  must  be  performed  by  a  certified  AAADM 
trained inspector. Tucker recommends this documented inspection be performed upon completion of the installation 
as well as, following the completion of every service call thereafter.  If service is not performed within one year of the 
previous service action, a routine AAADM inspection should be performed and documented. Under no circumstance 
should  the  product  operate  for  more  than  one  year  without  an  AAADM  inspection.  Tucker  does  NOT  recommend 
installation or service, on any of their automated pedestrian door products, by any individual who is not certified as 
an AAADM inspector.   

 

Following  the  installation  or  service  of  any  Tucker  automated  pedestrian  door  product,  if  it  is  deemed  unsafe,  or  is 
operating  in  an  unsatisfactory  manner  according  to  national  performance  standards  or  recommended  performance 
guidelines  as  defined  by  Tucker,  repairs  should  be  made  immediately.  If  an  immediate  repair  cannot  be  made,  the 
product  should  be  disabled,  and  appropriate  measures  should  be  taken  to  secure  the  door  in  a  safe  position  or  to 
enable the door to safely be used manually. During this situation, every effort should be made to notify the owner (or 
person responsible) of the condition and to advise on corrective actions that must be taken to return the product to 
safe operation. 

 

Tucker Auto-Mation HEADQUARTERS 

|

 

1081 3

rd

 Street,

 

North Versailles, PA 

15137 |

 

Tel. 1-855-8 TUCKER (1-855-888-2537) | www.tuckerauto-mation.com 

INSTALLATION PRECAUTIONS 

9

2

0

.1

0

0

3

.0

1

 

Содержание TAP

Страница 1: ...all dress plate E into the programmer module D Upon powering on the display on the TAP control will show a date time and the red LED s will illuminate to indicate current function positions The function of the door can be altered by pressing the desired button Pressing a button more than once toggles between functions for that button i e button number 4 can be used to command a door opening for te...

Страница 2: ...3 LOCK A Kit Lock I On Lock installed A Night The door is locked when On Off switch is OFF B One Way Night The door is locked when the On Off switch is in the Night or One Way position C Always Door is locked whenever it is closed II Off No lock installed 4 DIAGNOSTICS A Version III 2 Leaves Pairs A Off No controls linked to each other B On 2 controls are tied together Terminals 26 to 26 and 28 to...

Страница 3: ...ress OK 13 Select ON 14 Press OK 15 Press Down until EXIT displays 16 Press OK PROGRAMMING EXAMPLE Set OPENING SPEED to a value of 5 and choose to KEEP SETTINGS 1 Press the down arrow until ADVANCED MENU appears in the display 2 Press OK 5 times to scroll past setting the PASSCODE default is 000 3 OPERATION appears in the display 4 Press OK 5 CLOSING SPEED displays 6 Press Down arrow until OPENING...

Страница 4: ...iation of Automatic Door manufacturers AAADM This inspection must be performed by a certified AAADM trained inspector Tucker recommends this documented inspection be performed upon completion of the installation as well as following the completion of every service call thereafter If service is not performed within one year of the previous service action a routine AAADM inspection should be perform...

Отзывы: