PCM30U, PCM30U-OCH – User's, Operating and Maintenance Manual
E.1.10
PBS shorters and mechanical configuration
Jumper Meaning
XC1
Boundary scan connector
XC2, XC3
Line interface submodule connector
XC5
Display connector (optional)
XC6
LM local interface connector
XC7
M interface connector (management channel)
XC201
Connector for connecting of commands and alarm contacts
XJ2, XJ5
GND
XJ3 +5V
XJ4 +3,3V
XJ6
AUX1 – factory test point
XJ7
AUX2 – factory test point
XJ8
AUX4 – factory test point
DS1 Program
memory
E.1.10.1 Setting the functioning of ERR1 alarm opto-relay
XJ800 2-3
alarm = cloth
XJ801 1-2
XJ800
1-2
alarm = open
XJ801
2-3
E.1.10.2 Setting the functioning of ERR2 alarm elektromechanical relay
alarm = cloth
XJ802
1-2
alarm = open
XJ802
2-3
E.1.10.3 Setting command nominal input voltage
command jumper
24 V
48 V
110 V
220 V
1 XJ200
2-3
1-2,
3-4
1-2 —
2 XJ220
2-3
1-2,
3-4
1-2 —
3 XJ240
2-3
1-2,
3-4
1-2 —
4 XJ260
2-3
1-2,
3-4
1-2 —
5 XJ280
2-3
1-2,
3-4
1-2 —
6 XJ300
2-3
1-2,
3-4
1-2 —
7 XJ320
2-3
1-2,
3-4
1-2 —
8 XJ340
2-3
1-2,
3-4
1-2 —
9 XJ360
2-3
1-2,
3-4
1-2 —
10 XJ380
2-3
1-2,
3-4
1-2 —
Qvit XJ400 2-3
1-2,
3-4
1-2 —
Gray marked fields indicates factory default settings.
E.1.10.4 Configuration switches
SA3(1..4)
Unit identification for command group transmitted to A direction
SA4(1..4)
Unit identification for command group transmitted to B direction
SA7(1..4)-SA6(1..2) M management address in binary form (2
0
÷
2
5
)
M = SA7(1) x 1 + SA7(2) x 2 SA7(3) x 4 + SA7(4) x 8 SA6(1) x 16 + SA6(2) x 32
SA6(3)
Lock configuration of PBS functions to prevent inappropriate actions from the
management system
SA6(4)
Lock configuration of PWA functions to prevent inappropriate actions from the
management system
SA5(1..4)
For future use. Not assembled after January 2009
Power Channel Modules
E-23
446S037.914.14N00