background image

-8-

Connecting the cabtyre cable

 

Before connecting leads to the terminals, make certain the power supply 

is turned off (circuit breaker, etc.), to avoid electrical shock, shorting, or 

unexpected starting of the pump, leading to injury.

WARNING

Cabtyre cable 

 

•  If it is necessary to extend the cabtyre cable, use a core size equal to 

or larger than the original. This is necessary not only for avoiding a 

performance drop, but to prevent cable overheating which can result in fire, 

electrical leakage or electrical shock.

 

•  If a cable with cut insulation or other damage is submerged in the water, 

there is a danger of water seeping into the motor causing a short. This may 

result in damage to the pump, electrical leakage, electrical shock, or fire.

 

•  Be careful not to let the cabtyre cable be cut or become twisted. This may 

result in damage to the pump, electrical leakage, electrical shock, or fire.

 

• If it is necessary to submerse the connection leads of the cabtyre cable 

in water, first seal the leads completely in a molded protective sleeve, to 

prevent electrical leakage, electrical shock, or fire.

Do not allow the cabtyre cable leads to become wet.

Make sure the cable does not become excessively bent or twisted, and does not rub against a structure in a 

way that might damage it.

CAUTION

Grounding 

 

Do not use the pump without first grounding it properly. Failure to ground it 

can lead to electrical shock from an electrical leak or pump malfunction.

 

Do not attach the grounding wire to a gas pipe, water pipe, lightening arrestor 

or telephone grounding wire. Improper grounding can result in electrical 

shock.

WARNING
CAUTION

Electrical circuit diagrams

Red

 

Red

 

White 

White 

White 

Black 

Black 

Green 

Yellow 

Yellow 

U

V

W

S

U

V

W

S

G  S

Miniature Protector 

Coil 

Protector Circuit 

Leak Sensor 

Power · Control Cable 

Power Cable 

Star-delta start 

 

Do not use the pump if the cabtyre cable is worn or damaged, which can 

result in electric shock, shorting, or fire. 

Connect the leads of cabtyre cable to the control panel terminals as shown in the diagram, being careful not 

to let the leads become twisted together.

CAUTION

U

V

W

U

V

W

S

S

G  S

U

1

-Red 

V

1

-White 

U

2

-Black 

W

1

-Black 

Protector Circuit(Yellow) 

Leak Sensor Circuit(White) 

Protector Circuit(Yellow) 

W

2

-White 

V

2

-Red 

G-Green 

Star-delta start

Содержание LH Series

Страница 1: ...roduct to another party always be sure to include this operation manual as well If this operation manual should become lost or damaged ask your nearest dealer or Tsurumi representative for another copy Every effort has been made to ensure the completeness and accuracy of this document Please contact your nearest dealer or Tsurumi representative if you notice any possible error or omission The cont...

Страница 2: ...damage or the urgency of the precaution Note however that what is included under CAUTION may at times lead to a more serious problem In either case the categories pertain to safety related items and as such must be observed carefully WARNING CAUTION NOTE Explanation of Symbols PRECAUTIONS TO THE PRODUCT SPECIFICATIONS WARNING When transporting the product pay close attention to its center of gravi...

Страница 3: ...o so may result in damage to nearby walls floors and other equipment PRECAUTIONS DURING TEST OPERATION AND OPERATION CAUTION WARNING Never start the pump if somebody is present in the pump sump If an electrical leakage occurs it can cause electrical shock When inspecting the pump be sure to turn off the power supply earth leakage circuit breaker etc so that the pump may not start accidentally Fail...

Страница 4: ... where it was purchased or Tsurumi representa tive Improper repairs can result in electrical leakage electrical shock or fire Test operation stop OTHER PRECAUTION CAUTION Never use the product for potable water It may present a danger to human health Potable Water CAUTION Never insert a finger or any other object into the pump inlet holes Failure to observe this caution may lead to injury When the...

Страница 5: ... Cable Mechanical Seal Leakage Sensor Electrode Shaft Upper Shaft Sleeve Middle Shaft Sleeve Upper Labyrinth Ring Lower Shaft Sleeve Lower Labyrinth Ring Oil Plug Oil Lifter Discharge Pipe Lifting Eye Bolt Upper Pump Casing Lower Pump Casing Suction Mouth Cathodic Protection Plate Impeller Oil Oil Plug Cabtyre Cable Strainer Stand Oil Casing Bearing Housing Mechanical Seal Leakage Sensor Electrode...

Страница 6: ...den Water 0 40 C Pump Impeller Close Type Shaft Seal Double Mechanical Seal Bearing Ball Bearing Specifications Dry type Submersible Induction Motor 2 Pole Insulation Class F Protection System Built in Miniature Protector Leak Sensor Built in Electrode Turbine Oil VG32 Lubricant Connection to Piping JIS 10K Flange JIS 20K Flange Motor Example of nameplate 1 2 3 4 5 6 7 8 9 10 11 Submersible pump B...

Страница 7: ... resistance tester AC voltmeter AC ammeter clamp on type Bolt and nut tighteners Power supply connection tools screwdriver or box wrench Please read also the instructions that come with each of the test instruments Note Maximum allowable water pressure Do not use at greater than the water pressure shown in the table CAUTION Model JIS20K 0 5MPa 5kgf cm2 JIS10K Flange Specification LH6110 JIS20K LH4...

Страница 8: ... not collect in it 9 When performing pipe construction make sure welding sparks or paint do not contact the pump This pump is supplied without piping Use it with suitable piping material The tip of the hose discharge end should be located higher than the water surface If the end of the hose is submerged water may f low back to the pump when the pump is stopped and if the hose end is lower than the...

Страница 9: ...ctrical leakage electrical shock or fire Do not allow the cabtyre cable leads to become wet Make sure the cable does not become excessively bent or twisted and does not rub against a structure in a way that might damage it CAUTION Grounding Do not use the pump without first grounding it properly Failure to ground it can lead to electrical shock from an electrical leak or pump malfunction Do not at...

Страница 10: ...lectrical leak can result in electrical shock 1 Run the pump for a short time 1 2 seconds to check the direction of rotation The rotation is correct if the pump recoil direction is counter clockwise Always perform the rotation check in air not while the pump is submersed Running the pump in reverse direction while submersed may damage the pump resulting in electrical leakage or electrical shock WA...

Страница 11: ...eavy vibration and malfunctioning 1 Miniature Protector This protector is embedded inside the motor coil If the coil should overheat for any reason bending of the bimetal of the miniature protector triggers a signal which in turn causes an extermal circuit in the starting console or control panel to shut off the motor current When the temperature returns to normal the protector is automatically re...

Страница 12: ...ump back into service When the pump is left installed in water it should be run at regular intervals about once a week Note Interval Monthly EveryDay Yearly Inspection Item Every 2 to 5 years Measure operating current Measure insulation resistance Note If the insulation resistance has become notably lower than the precious inspection an inspection of the motor will be necessary Note Specialized kn...

Страница 13: ... oil and other waste products should be disposed of by a qualif ied agent in accord with applicable local laws The oil plug packing and O ring should be replaced each time the oil is inspected or changed Note Inspecting Oil Remove the oil plug and tilt the pump to drain a small amount of oil If the oil is milky white or has water mixed in with it the mechanical seal may be faulty In this case the ...

Страница 14: ...rts consult with your nearest dealer or Tsurumi representative Improper repairs can result in electrical leakage electrical shock fire or water leaks After reassembly always perform a test operation before resuming use of the pump Improper assembly will cause the pump to malfunction resulting in electrical shock or water leaks The procedure for disassembly and reassembly is shown here to the exten...

Страница 15: ...fter attaching the impeller and again after assembly is completed check to make sure the impeller rotates smoothly and that is does not rub against the suction mouth Note Note Oil Lifter Round Head Screw Mechanical Seal Oil Casing Upper Pump Casing Lower Pump Casing O Ring O Ring O Ring O Ring O Ring O Ring O Ring O Ring Suction Mouth Suction Mouth Packing Oil Plug Key Grease Plug Impeller Adjusti...

Страница 16: ...e the impeller impeller adjusting washer and the middle shaft sleeve from the shaft 6 Remove the upper pump casing Remove the hex nuts and spring washers then remove the upper pump casing from the pump and lift the upper shaft sleeve from the shaft 7 When absolutely necessary the mechanical seal can be removed by first removing the oil casing See also the manual that comes with the replacement mec...

Страница 17: ...sure the impeller rotates smoothly and that is does not rub against the pump casing The mouth rings are press f it into the upper pump casing and the lower pump casing and the labyrinth rings are press f it into the upper pump casing and the middle pump casing so it is necessary to replace the related pump casing s together when worn Note Note Note Note Oil Lifter Round Head Screw Mechanical Seal ...

Страница 18: ...1207B or equivalent on the middle pump casing and the lower pump casing when assembling the pump The place to be applied is the top part of each casing It is f illed with black in the drawing below Note Middle Pump Casing Lower Pump Casing ...

Страница 19: ...e sure the cabtyre cable extension is the proper standard 3 Check the name plate and replace the pump 4 Remove debris from the strainer 5 Repair or replace the motor 6 Place the pump on a block or other base to prevent sand from being sucked into it 1 Impeller is clogged 2 Low voltage 3 Wrong power frequency 4 Extended operation with a clogged strainer 5 Faulty motor 6 Excessive sand is discharged...

Страница 20: ...s Back to back Duplex Motor Specifications Dry type Submersible Induction Motor 2 Pole Insulation Class F Protection System Built in Miniature Protector Leak Sensors Built in Electrode and Float Lubricant Turbine Oil VG32 Connection to Piping JIS 10K Flange Standard specification 60Hz Model Bore mm Phase Starting Method Output kW Max Head m feet Max CAPACITY m3 min GPM Weight kg LH12185 300 3 Star...

Страница 21: ...AND INSPECTION Oil inspection and Oil change When the pump is tilted for inspecting or changing the oil pay careful attention to the center of gravity and weight of the pump Inspecting Oil Remove the oil plug and tilt the pump to drain a small amount of oil If the oil is milky white or has water mixed in with it the mechanical seal may be faulty In this case the pump will need to disassembled and ...

Страница 22: ...Bearing Lower Bearing Note Greasing generally is good for around 3 000 hours of use but this can vary depending on the use conditions Model Grease Type Initial Amount Refill Amount LH12185 RAREMAX SUPER Kyodo Yushi Co Ltd or equivalent 1 Upper 270g 9 52 oz Upper 300g 10 58 oz Lower 370g 13 15 oz Lower 400g 14 11 oz Item 1 Soap Type di Urea Base Oil Type Mineral Oil Viscosity 40oC 104oF 94mm2 s cSt...

Отзывы: