䠑䠊㻿㼜㼑㼏㼕㼒㼕㼏㼍㼠㼕㼛㼚㼟㻌

Model 

Item

㻌㻌 㻌 㻌 㻌 㻌 㻌 㻌 㻌

 

TSBSB05

 

TSBSB10

 

TSBSB30

 

TSBSB60

 

TSBSB100 TSBSB200

 

TSBSB300 

Current setting*

 

0.5

6A 

1

12A 

3

30A 

5

60A 

10

100A 20

200A  30

300A 

Time 
setting*

 

Start Time 

*

䠎 㻌

0.2

10s 

Shock Time 

*

䠎 㻌

0.2

5s 

Accuracy 

±10%

Full Scale

 

Control Power Supply 

24

240VAC/DC

No

 

polarity

±10

 50/60Hz 

Maximum motor voltage 

AC600V 50/60Hz

*

 

Current sensing method 

2 Integral Current Transformer 

Display 

Monitoring state,

MON

 lamp on 

Overcurrent state,

OC

lamp on 

Output 
Relay 

Contact 
constitution 

1a1b 

Contact rating 

3A

AC250V 

os

φ

䠙䠍

 

Recommend 
current 
(High-frequency 
operation ) 

0.2A or less

AC250V cos

φ

0.4 

Minimum 
allowable load*

 

DC10V,10mA 

Operation 
selecting*

 

䠠䠥䠬

 switch selection 

䠯䠯䠖

Normal operation/excitation; self-holding after trip 

㻌 㻌 㻌 㻌 㻌 㻌

   

㻌 㻌 㻌

䠯䠝䠖

Abnormal/excitation;  automatically reset after trip 

Expected life   

80,000 times at rated load 

 

Operating 
temperature 

20

䡚䠇

60

Υ

 

Ambient 
Environment

 

Storage 
temperature 

30

䡚䠇

70

Υ

 

Humidity 

45

85% RH without condensation 

Altitude 

2,000m or less 

Pollution degree 

Class 3, free from dust and corrosive gas 

Vibration 

5.9m

s

2

 or less 

Insulation 

Between casing and 
circuit 

Over 10M

Ω

DC500V Megger

 

Dielectric 
Strength 

Between casing and 
circuit

 

AC2000V

60Hz

1min 

Between contacts 

AC1000V

60Hz

1min 

Between circuits and 
contacts 

AC2000V

60Hz

1min 

Protection structure 

IP20 

Material 

Case 

Upper case

䠖䠬䠝䠒䠈

Lower case

䠖䠬䠝䠒䠒

 

Terminal cover 

䠬䠝䠒

 

Power Consumption 

 2W or less 

Mounting 

35mmDIN rail or Panel 

Weight 

Main body 

External CT

 

0.2 kg

㻌 䠄

0.5k

䡃䠅

 

*1. Current

Time setting ranges are settable ranges, not the upper or lower level of setting  knob. 

*2. The minimum value on the display is 1s, values smaller than 1s can be set with the dial.  

*3. In the case of inverter drive, there is a possibility of malfunction due to the distortion of the  current waveform. If the 

frequency is within the range of 30 to 60Hz, it can be used because the influence is minor.   

*4. Be sure to input minute electric currents through the relay when inputting an output relay contact directly into the PLC 

(Programmable logic controller), because there is a risk of contact failure due to minute electric current.   

*5. DIP switch is set on SS side when delivery.  
*6. When power off to reset, power off more than 1 seconnd.  
*7. Certificate standard : UL certification 

 UL508, CCC certification 

 GB14084.4 

Содержание TSBSB Series

Страница 1: ...WKLV 6 2 5 3OHDVH PDNH VXUH WKDW WKLV LQVWUXFWLRQ PDQXDO DFFRPSDQLHV WKH 6 2 5 WR WKH HQG XVHU 3OHDVH NHHS WKLV LQVWUXFWLRQ PDQXDO VDIH XQWLO WKLV SURGXFW LV GLVSRVHG RI 3URGXFW VSHFLILFDWLRQ LV VXEM...

Страница 2: ...Shock Relay Instruction Manual Model Identification Following 3 models include main body and external CT TSBSB100 TSBSB05 Main body TSB2CT100 External CT TSBSB200 TSBSB05 Main body TSB2CT200 External...

Страница 3: ...and protective equipment When carrying out operation test or periodic inspection make sure protective device functions properly Megger testing is conditional must be performed in accordance with inst...

Страница 4: ...3 TSBSB05 TSBSB10 TSBSB30 TSBSB60 TSBSB100 TSBSB200 TSBSB300 CT and main unit is wired before shipment Mounting hole dimension Install with 35mmDIN rail or mounting plate Screw Cover Mounting hole...

Страница 5: ...less Insulation Between casing and circuit Over 10M DC500V Megger Dielectric Strength Between casing and circuit AC2000V 60Hz 1min Between contacts AC1000V 60Hz 1min Between circuits and contacts AC2...

Страница 6: ...nstall an isolation transformer Remove terminal cover and use crimp terminal to connect terminal block and wire When connecting without crimp terminal tightening torque of 0 4 0 6N m is recommended to...

Страница 7: ...elect Shock Relay and the number of wires pass through according to set current values Main unit alone AC200VMotor AC400VMotor Capacity kW Motor Rate Current A Shock Relay No of wires that pass throug...

Страница 8: ...hole 15 55 TSBSB100 1 18 5 67 TSBSB100 1 22 78 TSBSB200 1 30 107 TSBSB200 1 54 TSBSB100 1 37 132 TSBSB200 1 66 TSBSB100 1 45 160 TSBSB300 1 80 TSBSB100 1 55 198 TSBSB300 1 99 TSBSB200 1 75 270 TSBSB30...

Страница 9: ...ity of the electromagnetic contactor MC which output contact opens and closes should be less than 200VA when throwing and less than 20VA when holding Part Names SHOCK TIME Shock time setting knob OC O...

Страница 10: ...Shock Relay output mode varies with DIP switch selection Basic Function A Current Operation current value Factory default setting MAX fully rihgt When the motor current exceeds the present CURRENT va...

Страница 11: ...ting Trouble Check Result Solution Mon does not light A1 A2 wiring Incorrect wiring Wire correctly A1 A2 voltage Not between 24 240V Supply 24 240V Does not trip at current knob MIN Wiring of CT Incor...

Страница 12: ...provided in the manual the Seller will repair and replace at no charge once the Goods are returned to the Seller This warranty does not include the following 1 Any costs related to removal of Goods f...

Отзывы: