Thank you for purchasing the Shock Relay TSBSB series.  
The Shock Relay is a current monitoring device that

quickly detects motor overload, thus 

protecting your equipment from costly damage. 
This instruction manual describes everything from installation to adjustment . Be sure to read 
this manual carefully before using your Shock R elay. 

 

䠎䠊㻯㼔㼑㼏㼗㼕㼚㼓㻌㼠㼔㼑㻌㼜㼍㼏㼗㼍㼓㼑㻌

Upon receiving the Shock Relay, please check the following: 

Check whether the model and specification conform to what you ordered.

Check to see no damages occurred during the delivery.

㻌 㻌

Package: Shock Relay, Instruction Manual 

 

Model Identification

 

ᵲᵱᵠᴾᵱᵠᴾᵎᵓ

 
 
 
 
 
 
 
 
 
 

 

*Following 3 models include main body and external CT 

  TSBSB100 

䞉䞉䞉

 TSBSB05

Main body

+TSB2CT100

External CT

 

  TSBSB200 

䞉䞉䞉

 TSBSB05

Main body

+TSB2CT200

External CT

 

   TSBSB300 

䞉䞉䞉

 TSBSB05

Main body

+TSB2CT300

External CT

 

 

CONTENTS

 

1. Preface 

…………………………

 

2. Checking the package 

……….

3.

Safety precaution

……………….

 

4. Dimensions...

…………………..

 

5.

Specifications

…………………

6. Installation   

…………………

.. 

7.

Wiring  

………………………

.. 

8.

Terminal function

……………

.. 

9

㻚㻌

Current Transformer

……….

....

10. Wiring diagram   

……………………

 

11. Part Names   

.………………………

.. 

12. Basic function

 

……………

..

..

.. 

13. Set up   

..…

.

……………..…..…

.

..…

14. Troubleshooting.....

…...…

..

.

.

 

15. Maintenance..........

…......…

..

..

 

16. Daily Inspection 

………

..

……

...

.. 

17. Periodic check 

………………………

 

18. Warranty

……………………….……

 









Page 

P

age 

Current setting range 
  05     0.5 

 6A 

    10              1 

12A 

    30              3 

30A 

    60              5 

60A 

*100     10 

100A 

*200     20 

200A 

*300     30 

300A 

SB series 

Shock Relay 

7
8
9

10
10
10
10
10
11

Содержание TSBSB Series

Страница 1: ...WKLV 6 2 5 3OHDVH PDNH VXUH WKDW WKLV LQVWUXFWLRQ PDQXDO DFFRPSDQLHV WKH 6 2 5 WR WKH HQG XVHU 3OHDVH NHHS WKLV LQVWUXFWLRQ PDQXDO VDIH XQWLO WKLV SURGXFW LV GLVSRVHG RI 3URGXFW VSHFLILFDWLRQ LV VXEM...

Страница 2: ...Shock Relay Instruction Manual Model Identification Following 3 models include main body and external CT TSBSB100 TSBSB05 Main body TSB2CT100 External CT TSBSB200 TSBSB05 Main body TSB2CT200 External...

Страница 3: ...and protective equipment When carrying out operation test or periodic inspection make sure protective device functions properly Megger testing is conditional must be performed in accordance with inst...

Страница 4: ...3 TSBSB05 TSBSB10 TSBSB30 TSBSB60 TSBSB100 TSBSB200 TSBSB300 CT and main unit is wired before shipment Mounting hole dimension Install with 35mmDIN rail or mounting plate Screw Cover Mounting hole...

Страница 5: ...less Insulation Between casing and circuit Over 10M DC500V Megger Dielectric Strength Between casing and circuit AC2000V 60Hz 1min Between contacts AC1000V 60Hz 1min Between circuits and contacts AC2...

Страница 6: ...nstall an isolation transformer Remove terminal cover and use crimp terminal to connect terminal block and wire When connecting without crimp terminal tightening torque of 0 4 0 6N m is recommended to...

Страница 7: ...elect Shock Relay and the number of wires pass through according to set current values Main unit alone AC200VMotor AC400VMotor Capacity kW Motor Rate Current A Shock Relay No of wires that pass throug...

Страница 8: ...hole 15 55 TSBSB100 1 18 5 67 TSBSB100 1 22 78 TSBSB200 1 30 107 TSBSB200 1 54 TSBSB100 1 37 132 TSBSB200 1 66 TSBSB100 1 45 160 TSBSB300 1 80 TSBSB100 1 55 198 TSBSB300 1 99 TSBSB200 1 75 270 TSBSB30...

Страница 9: ...ity of the electromagnetic contactor MC which output contact opens and closes should be less than 200VA when throwing and less than 20VA when holding Part Names SHOCK TIME Shock time setting knob OC O...

Страница 10: ...Shock Relay output mode varies with DIP switch selection Basic Function A Current Operation current value Factory default setting MAX fully rihgt When the motor current exceeds the present CURRENT va...

Страница 11: ...ting Trouble Check Result Solution Mon does not light A1 A2 wiring Incorrect wiring Wire correctly A1 A2 voltage Not between 24 240V Supply 24 240V Does not trip at current knob MIN Wiring of CT Incor...

Страница 12: ...provided in the manual the Seller will repair and replace at no charge once the Goods are returned to the Seller This warranty does not include the following 1 Any costs related to removal of Goods f...

Отзывы: