3
Chapter 2
Setting-Up
Supplying Power to the V
ELOCI
C
ALC
The V
ELOCI
C
ALC
can be powered in one of two ways: four size AA batteries
or the optional AC Adapter.
Installing the Batteries
Insert four AA batteries as indicated by the diagram located on the
inside of the battery compartment. TSI ships the unit with alkaline
batteries. The V
ELOCI
C
ALC
is designed to operate with either
alkaline or NiCd rechargeable batteries. Carbon-zinc batteries are
not recommended because of the danger of battery acid leakage.
Table 2-1 Typical Battery Life at 20°C
Air Velocity
Alkaline
NiCd
(ft/min)
(m/s)
(hrs)
(hrs)
100
0.5
7.0
5.0
1000
5.0
4.4
3.5
9000
45.0
2.4
2.4
Using the AC Adapter
When using the AC adapter, the batteries (if installed) will be
bypassed. The AC adapter is not a battery charger.
Selecting the Display Units
The V
ELOCI
C
ALC
is capable of displaying the measured values in several
different measurement units. The choices of measurement units are shown
in Table 2-2.
Table 2-2. Choices of Measurement Units
Velocity Temperature/
Dew Point
Flow Rate
Pressure
ft/min °F ft
3
/min in.
H
2
O
m/s °C m
3
/hr mm
Hg
l/s
kPa
To change the display units on your V
ELOCI
C
ALC
, refer to Appendix B, DIP
Switch Settings.
Using The Telescoping Probe
The telescoping probe, mounted on the side of the V
ELOCI
C
ALC
, contains
the velocity, temperature, and humidity sensors (humidity sensor, Model
8360 and 8388 only). The probe is shipped pointing downward in the
stowed position. The probe can be used either mounted on the V
ELOCI
C
ALC