A. Gap Mode
25
Press the
and
buttons to scroll the cursor to the media type and press
the
button to enter the sensor calibration mode.
Note: If printing from enclosed software/driver, the software/driver will send
out the GAP or BLINE command, which will overwrite the sensor type
setting set from the front panel.
A-1 Automatic
When enter the [Automatic] option, you will see following message, and
printer will feed 2 to 3 gap labels to calibrate the sensor sensitivity
automatically. When calibration is completed, the LCD screen will return to
the previous menu.
A-2 Manual
In case “Automatic” sensor calibration cannot apply to the media, please
use “Manual” function to calibrate the gap sensor manually.
When enter [Manual] option, you will see following message. Please
complete there steps
:
Paper Len.
00812 dot
1. Press the
button to move
the cursor from left digit to right digit,
and press the
button to set
the value from “0” to “9” and the “dot/
mm/ inch”. Press the
button to set the paper length into the
printer.
Calibration 1/4
>
Gap Mode
Bline Mode
Cont. Mode
Gap Mode 1/4
>
Automatic
Manual
Pre-Printed
Gap Mode
Automatic
Gap Mode 2/4
Automatic
>
Manual
Pre-Printed