Fault Diagnosis
WARNING - Before undertaking maintenance operations or adjustments switch off
machine and unplug from the electricity supply
Problem
Reason
Remedy
ELECTRICAL SYSTEM
No electrical power
1. Defective power cord.
2. Fuse blown.
1. Replace
2. Replace fuse. Unplug any
equipment using the same circuit.
Switch is turned on. Intermittent
power to motor(s).
1. Faulty electrical cable.
2. Defective switches.
3. Loose terminal
1. Replace cable
2. Contact service agent
3. Contact service agent.
VACUUM SYSTEM
Vacuum motor on
Little or no vacuum on wand
head.
1. Drain valve open
2. Defective vacuum hose
3. Vacuum disconnected
1. Close drain valve. Recovery tank
lid must be closed
2. Repair or replace hose. Remove
kinks in vacuum hose.
3. Open machine, connect vacuum
hose to recovery tank.
Not enough vacuum power at
the machine.
1. Damaged recovery tank
lid.
2. Lint clogging ball - type
shutoff screen
3. Vacuum hose connection
between stand pipe and
vacuum motor.
4. Vacuum motor exhaust
blocked.
1. Replace
2. Remove screen. Clean out fibres
and accumulated dirt.
3. Check for leaks around clamps
and cuffs (tighten). Replace
damaged hose(s).
4. Check air flow by removing hose
from machine and feel the exhaust
under the machine. Remove
obstruction.
Motor running and no vacuum.
No exhaust from the blowport
1. Faulty vacuum motor.
2. Float valve blocked.
1. Replace.
2. Clean water shutoff screen.
Premature closing of ball type
shutoff.
Ball type shutoff failing to
release after ball recovery tank
is drained.
1. Dirty or clogged shut off
filter screen.
2. Ball coated with detergent
or other foreign material.
3. Screen slightly out of
round.
1. Remove and clean screen.
2. Remove and rinse ball with clean
water.
3. Bend screen by squeezing slightly
by hand until there is an obvious
space between ball and inside of
screen.
Foam/dirty solution - coming out
of vacuum exhaust port.
1. Foam from carpet by
passing water shutoff.
2. Elbow in vacuum tank is
not positioned correctly
1. Use additional defoamer.
2. The elbow should be pointed
directly at the side wall of the tank
away from the ball type shutoff.