Troubleshooting
15
• The switch is off.
• Not enough fuel.
• The oil level is very low or is has no oil.
• Appliances connected to the machine.
• Gasoline is not reaching the carburetor.
• There is no spark in the spark plug.
• Oil level is too low.
• The overload thermal protector has not been
re-established.
• Some of the appliances are not working.
• Damaged thermal protector.
• The switch is in the OFF position.
• Partial short circuit in the motor winding.
The motor is not
starting.
The motor starts but
stops unexpectedly.
There is no power in
the connection panel
outputs.
The machine has no
voltage.
There is no arc onset
or is difficult to light
the arch after the
welder in on.
Problem
Cause
Solution
• Turn on the switch.
• Fill up the fuel tank.
• Check motor oil level as indicated in page 9.
• Disconnect all the appliances from the
connection panel before starting the machine’s
motor.
• With the full fuel tank verify the flow of fuel in
the carburetor:
1. Set under the carburetor an adequate
container to receive gasoline and use a funnel to
prevent fuel spills.
2. Remove the drain bolt. Fuel shall flow freely.
Otherwise go to a Authori-
zed Service Center.
• Verify the spark in the spark plug:
1. Disconnect the spark plug cable, clean dust
around the spark plug and remove it.
2. Connect the cable to the spark plug.
3. Turn on the motor switch.
4. Make contact with the spark plug side
electrode into any metallic and free of oil part in
the motor. It is important to
make this test in ventilated areas and with no fuel
spillage. Otherwise, an explosion can occur.
5. Pull the starter handle to generate a spark
between the spark plug central electrode and the
metallic part. If there is no spark replace the
spark plug.
6. If there is no spark with the new spark plug go
to a Authorized Service
Center.
• Check the motor oil level as indicated in page 9.
Restart the motor again.
• Verify the overload thermal protector is ON.
• Check the appliances before connecting. Repair
any damaged appliance before plugging into the
machine.
• Go to a Authorized Service
Center to replace it.
• Set the switch in the ON position.
• Go to a Authorized Service
Center to repair the machine.
CAUTION
ENGLISH
If the problems persist despite carrying out the recommended corrective actions,
contact a Authorized Service Center
Содержание SOT-145G
Страница 17: ...17 ESPA OL Notas...
Страница 18: ...Notas 18 ESPA OL...
Страница 36: ...16 Electrical diagram ENGLISH...
Страница 37: ...17 Notes ENGLISH...
Страница 38: ...18 ENGLISH Notes...