3
Technical Data
14358
Code
Description
SOT-145G
Engine Driven Welder / Generator
Output
Dimensions
Fuel Requirements
• The machine is built with an air-cooled 4-stroke motor
using pure unleaded gasoline.
• Never mix oil with the fuel.
• Never use fuels mixed with
ethyl-alcohol (gasohol), ethanol, or methane. These fuels
attract humidity which causes separation and acid build
up while in storage. Acidity can damage the motor fuel
system when in storage.
• In order to not having issues with the motor, the fuel
system shall be emptied before storing the machine for
periods longer than 30 days or more. Drain the gasoline
tank, start the motor and leave it running until the fuel
lines and carburetor are empty.
WARNING
Do not use the equipment in closed spaces.
Prevent from breathing the accumulated
potentially mortal carbon monoxide gases It is an odorless
toxic gas.
Never smoke near fuel.
Do not smoke near the filling-up
zone or when operating the equipment.
DANGER
DANGER
One 120 V polarized double contact, One 240 V two-phase
Voltage
120 V / 240 V
Frequency
60 Hz
Maximum Starting Power
6 Hp
Maximum Operation Power
5.3 Hp
Sound Level
94 dB at 13 ft
Work Cycle
30 min rest per tank consumed in continuous work in rated power.
Open Circuit Voltage
Current Adjustment Level
40 A - 145 A
75 V
Protection Grade
IP21S
Duty Cycle
35% | 3,5 min work per 6,5 min rest
439 cc 4-stroke
Gasoline
Motor Rated Power
Motor
Generator
Welder
Fuel
3.9 gal
253.5 lb
27.5” x 22.8” x 28.7”
Fuel Tank
0.99 gal/h
Fuel Consumption
Weight
14 Hp
The next season use fresh gasoline.
• Never pour inside the fuel container any motor or
carburetor cleaners. These can cause permanent damage.