E609EN_01.DOC
Maintenance
17
¾
Hold a piece of paper in front of the exhaust air vent in the
motor housing when the machine is running.
The oil supply is sufficient when oil spots appear.
When there is no oil mist lubrication device available:
¾
Fill the air inlet bore hole with 0.5-1 ccm of oil every two hours.
Recommended lubricant:
•
BP Energol RD 80 (-15° to +10 °C/+5° to +50 °F).
•
BP Energol RD-E80 (+10° to +30 °C/+50° to +86 °F).
•
Shell Tellus Oil 15 (-15° to +10 °C/+5° to +50 °F).
•
Torculla 33 (+10° to +30 °C/+50° to +86 °F).
Note
Secure the compressed air hose against undesired movements
using a compressed air safety device.
5.3 Replacing
fins
Worn fins decrease machine performance.
¾
Have the fin set checked and replaced as needed by a
qualified technician.
Note
Only use original replacement parts and observe the information
on the rating plate.
Checking the oil supply