Installing the OCB transfer device
1714400_ANGLE_MEAS
URING_SYSTEM_OCB
Installing an option
1. In the “Option“ field, click on the respective control element.
2. Select “File Mode“ in the “Request Mode“ field.
3. Enter the 16-digit voucher identifier for the option in the
“Voucher entry“ field and click on the “Generate UIR“ button.
A UIR text file is created which contains the code for requesting.
4. Send the UIR text file to TRUMPF Maschinen Austria.
5. Receive the license file from TRUMPF Maschinen Austria and
transfer it to a USB stick.
6. In the option program, select the requested option, select “File
mode“ and click on the “Import and validate certificate“ button.
7. In the file dialog that is now displayed, select the received
license file on the USB stick and click on “OK“.
If this is carried out successfully, the message “License
successfully imported“ is displayed and the license status changes
to “Registered“.
8. Click on “OK“ above in the window.
9. Change to the start menu and select “Suspend“.
The control carries out a restart.
10. Insert the OCB USB stick into a USB plug socket and restart
the control.
11. Select PROGRAMMED OPERATION.
12. At “11. Program data“, “Serial connection“, “Device for angle
measurement“, select
Mit. 187-50x U-WAVE
.
Note
The OCB USB stick must remain plugged in during the entire
transfer. In the event of interruption, a restart of the control has to
be done.
13. Measure the angle at the bending part.
14. Change to angle correction at the control.
15. Press the OCB button on the goniometer.
or
Press the DATA/HOLD button on the goniometer.
The green position LED lights up for a few seconds.
The displayed angle is transferred to the control. The LEDs on
the OCB transfer device and at the OCB USB stick light up
briefly.
16. Press ENTER.
Starting angle transfer