6
Installing the OCB transfer device
1714400_ANGLE_MEAS
URING_SYSTEM_OCB
By using a 5-pole mini-B USB plug cable (even if the
transfer device is installed at the goniometer), the
rechargeable battery of the transfer device can be charged by any
standard 5-volt mobile phone charger or by any computer with a
USB socket. No data is exchanged by this USB connection; it is
only used to recharge the LiPo rechargeable battery. The transfer
device remains fully operative while it is being recharged.
LED status displays on the OCB radio
measured value transfer device
Rechargeable battery status
Rechargeable battery
LED
The rechargeable battery and the OCB radio
measured value transfer device are both ready for
use
flashes slowly, green
The rechargeable battery is almost empty
flashes slowly, red
The rechargeable battery is empty The device
switches itself off again immediately
flashes 1 second, red
The source voltage is plugged in and the
rechargeable battery is completely charged
lights up, green
The rechargeable battery can not be charged
since the temperature is too high or the battery is
defective
flashes quickly, red
The charging voltage is too low
lights up, red
Radio transfer status
Radio links LED
If the transfer was successful.
flashes 1 second, green
If the transfer has failed after 5 attempts.
flashes 1 second, red
If data is present from the goniometer and the
transfer is in progress.
flashes, yellow
If the goniometer is not switched on and, as a
result, no transfer is in progress.
after a short time
flashes 1 second, red
OCB USB stick
The USB stick (USB-A plug) receives the angle values,
administers the statuses of the position LEDs and the
registered OCB radio measured value transfer device and
prepares communication for the USB interface. The
communication is done via a virtual COM, which is created
by the FTDI-USB driver, with a baud rate of 57k6. USB traffic
is shown by flashing of the yellow LED.
Tab. 1
Tab. 2
Содержание TruBend 3000 Series
Страница 2: ...2 1714400_ANGLE_MEAS URING_SYSTEM_OCB...