13
Technical Data
Battery voltage
DC voltage 10 V – 15 V
Output voltage
Output battery II, DC voltage controlled 14.2 V
Output refrigerator, DC voltage not controlled
Output current
7 A
Temperature
Ambient temperature from -25 °C to +35 °C
During operation, the casing may heat up to around 70 °C
Cooling
By convection
Configuration
In accordance with the VDE provisions and the device
safety law
Dimensions / weight
Casing
Aluminum
Length
156 mm
Width
119 mm
Height
66 mm
Weight
0.55 kg
The right to effect technical modifications is reserved!
Troubleshooting
Error
Rectification
The battery
does not
charge.
Test and if necessary replace the 15 A
fuse – output battery II.
Check the connections and ensure that
they are connected to the right terminals.
Check the coupling plug.
No power
supply to the
refrigerator
Test and if necessary replace the 15 A
fuse – refrigerator.
Check the connections and ensure that
they are connected to the right terminals.
Check the coupling plug.
If these measures do not solve the problem, please
contact the Truma Service Centre.