Technical data

Protection type / protection class 

IP21 / class I

Water capacity

14 litres

Rated water pressure

400 kPa

Maximum working water pressure / temperature 

P&T relief valve setting

500 kPa – 99 °C – 10 kW

Type of gas

Universal LPG

Test point pressure

2.75 kPa

Nominal heat input

5.2 MJ/h (H

S

)

Nominal heat output

1.2 kW

Gas consumption

5.2 MJ/h 

Injector size

0.70 mm

Heating up time from approx. 20 °C up to approx. 65 °C

(14 litres)

Gas operation: approx. 45 min.

Electrical operation: approx. 40 min.

Gas and electrical operation: approx. 28 min.

Power consumption 12 V 

Ignition: 0.160 A

Heating up: 0.12 A

Stand-by: 0.05 A

Power consumption 230 V   / 240 V 

Heating up: 5.7 A / 5.9 A, 1300 W / 1415 W

Weight (empty) 14 litres

BGA: 

 

 

7.7 kg 

BGA with peripheral devices:  

8.6 kg 

BGEA: 

 

 

8.1 kg 

BGEA with peripheral devices: 

9.1 kg 

Water pressure reducer 

Flow range water:   0 – 10 litres/min.

Maximum inlet pressure:  700 kPa

Maximum outlet pressure:  200 kPa

The right to make technical modifications is reserved!

Dimensions

cut ou

t

2

4

5

129

32

4

16

8

47

30

109

24

2

5

5

18

Fig. 7

water

connections

gas connection

with test point

electronic

cowl

cut ou

t

PTR Valve

connection

36

0

347

92

383 

17

4

Minimum 120 

Fig. 8

(All dimensions in mm)

Содержание UltraRapid LPG

Страница 1: ...Operating instructions To be kept in the vehicle Truma UltraRapid LPG and 230 V 240 V Electric Storage Water Heater...

Страница 2: ...ice must only be installed and repaired by a licensed person Symbol indicates a possible hazard Note containing information and tips Model Truma UltraRapid Gas BGA 14 from 01 2022 Truma UltraRapid Gas...

Страница 3: ...ored in the installation area since excess temperatures may occur there under certain circumstances During the initial operation of a brand new appliance or after it has not been used for some time a...

Страница 4: ...entire water supply through with clean warm water Always mount the cowl cap when the water heater is not being operated Drain the water heater if there is a risk of frost Warranty claims will not be...

Страница 5: ...caps must not be used Drain the water heater if there is a risk of frost Warranty claims will not be accepted if this is ignored Red indicator lamp Fault The red indictor lamp a lights up if there is...

Страница 6: ...hing on the heater does not operate No 240 V supply voltage Excess temperature thermostat has responded Connect the caravan to the site supply and or check residual current circuit breaker The electri...

Страница 7: ...Gas and electrical operation approx 28 min Power consumption 12 V Ignition 0 160 A Heating up 0 12 A Stand by 0 05 A Power consumption 230 V 240 V Heating up 5 7 A 5 9 A 1300 W 1415 W Weight empty 14...

Страница 8: ...ged or destroyed by fire flood landslide act of God terrorism or other inevitable accident improperly installed assembled or commissioned contra ry to the instructions for operation and installation i...

Страница 9: ...9 Gas Control Panel 230 V AC 240 V AC Truma UltraRapid spare parts When ordering spare parts please always state the serial number and year of manufacture...

Страница 10: ...N brown BU blue GN green GY green yellow OG orange RD red WH white YE yellow WH BN GN YE GY Electrical Connection Diagram Truma UltraRapid Hot Water System Safety Valve PC Push Coil HC Holding Coil RD...

Страница 11: ......

Страница 12: ...0 07 2018 E Mail service leisure tec com au In Australia always notify Service Australia if problems are encountered in other countries the relevant service partners should be contacted www truma com...

Отзывы: