Fuses

The water heater 12 V fuse is on the PCB on the water heater.

Important note

Only replace the miniature fuse on the PCB with a fuse of the 

same type: 1.6 A (slow action).

1.6 A

Fig. 6

If there is a defect in the electronics, return the PCB well 

padded. If you fail to pack it correctly, the warranty shall 

no longer be valid.

Only use original Truma UltraRapid - PCB as spare parts!

Fault finding

Gas operation

Symptom

Cause

When switching on, the heat-

er does not operate.

 

– No 12 V   supply voltage.

Check the power supply (operation voltage min. 10.5 V).

Check the Truma UltraRapid fuse (refer to maintenance 

“Fuses”).

When switching on, the heat-

er does not operate and the 

red lamp lights up  

after approx. 30 secs. 

 

– Cowl cover fitted. 

 

– Air in the gas supply.

 

– No gas supply. 

 

– Incorrect gas pressure.

Remove cowl cover and / or clear any obstruction. 

Check gas valves and gas cylinder.

To unlock (and purge air), switch off the appliance, wait  

5 minutes, and switch on again.

Heater operates for a pro-

longed time and then 

the red lamp lights up.

 

– Excess temperature  

thermostat has responded.

Check water level, refill if required (close drain valve).

To unlock, switch off the appliance, wait 5 minutes, and 

switch on again.

Electrical operation

Symptom

Cause

When switching on, the 

heater does not operate.

 

– No 240 V   supply 

voltage.

 

– Excess temperature  

thermostat has responded.

Connect the caravan to the site supply and / or check residual 

current circuit breaker.

The electrical heating element is fitted with an excess tem-

perature cut-out.

In the event of an impermissible dry run or overheating 

of the water due to an error, the voltage supply will be in-

terrupted. In this case, a qualified service person must be 

contacted.

DANGER 

The operation of the thermal cut-out indicates a possi-

bly dangerous situation. Do not reset the thermal cut-out un-

til the water heater has been serviced by a qualified person.

Operating in gas mode is still possible.

Water supply

Symptom

Cause

Water drips from the  

P&T relief valve.

 

– Water pressure too high.

 

– Lime or dirt under the 

P&T relief valve seat.

Check water pressure (max. 400 kPa), use a pressure reduc-

er when connected to central water supply.

Allow the appliance to cool and then slowly raise the test 

lever (Fig. 2a – 4a) to flush the water system and attempt to 

force dirt or foreign matter out of the P&T relief valve seat. 

Replace P&T relief valve. This must be performed only by a 

certified service technician.

When opening the cold  

water tap, hot water  

comes out.

 

– Hot water flows back 

through the cold water 

supply.

Fit a non-return valve in the cold water supply (refer to instal-

lation instructions “Water connection”).

If fault persists, please contact Service Australia.

Содержание UltraRapid LPG

Страница 1: ...Operating instructions To be kept in the vehicle Truma UltraRapid LPG and 230 V 240 V Electric Storage Water Heater...

Страница 2: ...ice must only be installed and repaired by a licensed person Symbol indicates a possible hazard Note containing information and tips Model Truma UltraRapid Gas BGA 14 from 01 2022 Truma UltraRapid Gas...

Страница 3: ...ored in the installation area since excess temperatures may occur there under certain circumstances During the initial operation of a brand new appliance or after it has not been used for some time a...

Страница 4: ...entire water supply through with clean warm water Always mount the cowl cap when the water heater is not being operated Drain the water heater if there is a risk of frost Warranty claims will not be...

Страница 5: ...caps must not be used Drain the water heater if there is a risk of frost Warranty claims will not be accepted if this is ignored Red indicator lamp Fault The red indictor lamp a lights up if there is...

Страница 6: ...hing on the heater does not operate No 240 V supply voltage Excess temperature thermostat has responded Connect the caravan to the site supply and or check residual current circuit breaker The electri...

Страница 7: ...Gas and electrical operation approx 28 min Power consumption 12 V Ignition 0 160 A Heating up 0 12 A Stand by 0 05 A Power consumption 230 V 240 V Heating up 5 7 A 5 9 A 1300 W 1415 W Weight empty 14...

Страница 8: ...ged or destroyed by fire flood landslide act of God terrorism or other inevitable accident improperly installed assembled or commissioned contra ry to the instructions for operation and installation i...

Страница 9: ...9 Gas Control Panel 230 V AC 240 V AC Truma UltraRapid spare parts When ordering spare parts please always state the serial number and year of manufacture...

Страница 10: ...N brown BU blue GN green GY green yellow OG orange RD red WH white YE yellow WH BN GN YE GY Electrical Connection Diagram Truma UltraRapid Hot Water System Safety Valve PC Push Coil HC Holding Coil RD...

Страница 11: ......

Страница 12: ...0 07 2018 E Mail service leisure tec com au In Australia always notify Service Australia if problems are encountered in other countries the relevant service partners should be contacted www truma com...

Отзывы: