– Any modifications to the unit, including ac-

cessories and cowl, or the use of spare parts 
and accessories that are important to the 
operation of the system that are not original 
Truma parts and failure to follow the installa-
tion and operating instructions will void the 
warranty and release Truma from any liabil-
ity claims. It also becomes illegal to use the 
appliance, and in some countries this even 
makes it illegal to use the vehicle.

 

– Any work involving connection or intercon-

necting wiring must be carried out by a li-
censed electrician. If the mains cable (supply 
cord) is damaged, it must be replaced by the 
manufacturer, its service agent or similarly 
qualified persons in order to avoid a hazard.

 

– Before accessing terminals, please en-

sure all supply circuits are disconnected 
(i.e. 230 V

 

– 240 V

 and 12 V

) and that 

the gas supply is securely turned off.

 

– The operating pressure for the gas supply is 

2.75 kPa (AUS – Propane) and must corre-
spond to the operating pressure of the appli-
ance (see data plate).

 

– LPG systems and pressure regulators must 

comply with the technical and administrative 
regulations of the country in which the appli-
ance is used. For your own safety it is  absolutely 
necessary to have the complete gas installation 
regularly checked by a licensed person (at least 
every 2 years). The vehicle owner is always re-
sponsible for arranging the gas inspection.

 

– Do not operate when travelling.

 

– Do not operate the water heater when refuel-

ling the vehicle and when it is in the garage.

 

– Items sensitive to heat (e. g. spray cans) 

must not be stored in the installation area, 
since excess temperatures may occur there 
under certain circumstances.

 

– During the initial operation of a brand new 

appliance (or after it has not been used for 
some time), a slight amount of fumes and a 
slight smell may be noticed for a short while.

 

– This device may be used by children aged 8 

years or above and by persons with reduced 
physical, sensory or mental capabilities or lack 
of experience and / or knowledge, only if they 
are supervised or have been given instruction 
with regard to the safe use of the device and 
have understood the potential risks. Children 
must not use the device as a toy. 

 

– In order to avoid a hazard due to inadvertent 

resetting of the thermal cut-out, this appli-
ance must not be supplied through an exter-
nal switching device, such as a timer, or con-
nected to a circuit that is regularly switched 
on and off by the utility.

Danger
 – 

Failure to operate the P&T relief valve 

(Fig. 1- 4) at least once every six months may 
result in the water heater splitting. Continuous 
leakage of water from the valve may indicate a 
problem with the water heater!

 

– Water may drip from the discharge pipe of 

the  P&T relief valve and this pipe must be 
left open to the atmosphere.

 

– The P&T relief valve is to be operated regu-

larly to remove lime deposits and to ensure 
that it is not blocked.

 

– Any discharge pipe connected to the 

P&T relief valve is to be installed in a con-
tinuously downward direction and in a frost 
free ambient.

 

– Always remove the cowl cover prior to oper-

ating the water heater.

 

– Do not place articles on or against this 

appliance.

 

– Do not use or store flammable materials 

near this appliance.

 

– Do not spray aerosols in the vicinity of this 

appliance while it is in operation.

 

– Do not modify this appliance.

Содержание UltraRapid LPG

Страница 1: ...Operating instructions To be kept in the vehicle Truma UltraRapid LPG and 230 V 240 V Electric Storage Water Heater...

Страница 2: ...ice must only be installed and repaired by a licensed person Symbol indicates a possible hazard Note containing information and tips Model Truma UltraRapid Gas BGA 14 from 01 2022 Truma UltraRapid Gas...

Страница 3: ...ored in the installation area since excess temperatures may occur there under certain circumstances During the initial operation of a brand new appliance or after it has not been used for some time a...

Страница 4: ...entire water supply through with clean warm water Always mount the cowl cap when the water heater is not being operated Drain the water heater if there is a risk of frost Warranty claims will not be...

Страница 5: ...caps must not be used Drain the water heater if there is a risk of frost Warranty claims will not be accepted if this is ignored Red indicator lamp Fault The red indictor lamp a lights up if there is...

Страница 6: ...hing on the heater does not operate No 240 V supply voltage Excess temperature thermostat has responded Connect the caravan to the site supply and or check residual current circuit breaker The electri...

Страница 7: ...Gas and electrical operation approx 28 min Power consumption 12 V Ignition 0 160 A Heating up 0 12 A Stand by 0 05 A Power consumption 230 V 240 V Heating up 5 7 A 5 9 A 1300 W 1415 W Weight empty 14...

Страница 8: ...ged or destroyed by fire flood landslide act of God terrorism or other inevitable accident improperly installed assembled or commissioned contra ry to the instructions for operation and installation i...

Страница 9: ...9 Gas Control Panel 230 V AC 240 V AC Truma UltraRapid spare parts When ordering spare parts please always state the serial number and year of manufacture...

Страница 10: ...N brown BU blue GN green GY green yellow OG orange RD red WH white YE yellow WH BN GN YE GY Electrical Connection Diagram Truma UltraRapid Hot Water System Safety Valve PC Push Coil HC Holding Coil RD...

Страница 11: ......

Страница 12: ...0 07 2018 E Mail service leisure tec com au In Australia always notify Service Australia if problems are encountered in other countries the relevant service partners should be contacted www truma com...

Отзывы: