To prevent dangerous gas from accumulating, the gas pressure
regulator must be installed in a well-ventilated space� Ventila-
tion must be guaranteed at all times� Do not close ventilation
openings�
Close the gas cylinder if the vehicle is parked in a garage�
Close the gas cylinder during transport on ferries, etc�
Chemical residues that may be contained in inferior liquid gas may
damage the product, shorten its lifespan and even lead to leaks�
A gas filter must be installed upstream of the gas pressure regu-
lator inlet to provide reliable protection against dirt or oil contami-
nation�
Gas pressure regulators, automatic switchover equipment and high-
and low-pressure hoses must be replaced no later than 10 years after
the date of their manufacture in order to guarantee fault-free func-
tioning of the gas system under normal operating conditions� Earlier
replacement may be required if this is prescribed by national regu-
lations� Truma accepts no responsibility for malfunctions, damage,
injury or accidents resulting from operating gas pressure regulators,
automatic switchover equipment and high- and low-pressure hoses
that are more than 10 years old�
Replace gas pressure regulators and high- or low-pressure hoses
in good time according to applicable regulations� The user is
responsible for this�
Observe national regulations�
When changing a gas cylinder, a gas hose or a filter pad, flammable
gas may escape:
Do not use any naked flames or open fire�
Do not smoke�