9
EN
cylinders simultaneously). We recommend that you do not operate
the cylinder if the control knob is in the intermediate position.
Removal status
In the normal position (operating cylinder on the left, reserve cylinder
on the right), the following display will be seen:
– Status display (12) is green = gas taken from the left cylinder (oper-
ating cylinder).
– Status display (12) is red = gas is taken from the right cylinder
(reserve cylinder); check the connection and fill level of the left
cylinder.
Changing the gas cylinder
Use the included screw aid (9) to attach and remove the high-pres-
sure hoses (3). It will help you generate the necessary tightening
torque and will prevent damage to the union that may otherwise re-
sult from using an improper tool.
Residual gas: No smoking, no naked flames!
– Close the valve (1) of the empty gas cylinder (2).
– Remove the high-pressure hose (3) from the gas cylinder (2) and
remove the clip-on adapter, if present.
– Attach the high-pressure hose (3) to the full gas cylinder and fit the
clip-on adapter, if present. Change the filter pad of the gas filter.