Connection diagrams
• The drawings are not intended to describe a complete system. It is up to the certified service technician to determine
the necessary components for and configuration of the particular system being installed (for example, an additional
surge protector).
• The drawings do not imply compliance with state or local code requirements or regulations. It is the certified service
technician’s responsibility to make sure that the installation is fully compliant with all state or local code requirements
or regulations.
AquaGo comfort
Hot Water
Outlet
Cold Water
Inlet
Maximum pressure 450 kPa
Inlet pressure 2.62 - 3.49 kPa
LP gas supply (propane only)
Top
Instant
Water Heater
C*
A*
B*
* Bypass kit for winterising (not in scope of delivery)
Tap 1
Tap 2
Shower
Gas rear connection
Gas side connection
Fig. 17
AquaGo comfort plus
Circulation
Line Inlet
Cold Water
Inlet
Maximum pressure 450 kPA
Inlet pressure 2.62 - 3.49 kPa
Top
Hot Water
Outlet
Instant
Water Heater
C*
D*
A*
E*
B*
* Bypass kit for winterising (not in scope of delivery)
Drain Line
LP gas supply (propane only)
Gas side connection
Tap 1
Tap 2
Shower
Gas rear connection
Fig. 18
Electrical connection for all models
Maximum length of the power supply cable (including cables for the optional switch):
• for 16 AWG or 1.5 mm² MWG: max. 12 m (bidirectional)
• for 14 AWG or 2.0 mm² MWG: max. 20 m (bidirectional)
12 VDC
Ripple < 1 V
pp
12 VDC
Power
Supply
Instant
Water Heater
+
+
-
-
7.5 A
Switch ON - OFF
(Rating: ≥ 7.5 A)
Optional:
Control
panel /
Diagnosis
Fig. 19