10
Maintenance
Replacing Actuators
If one actuator needs to be replaced it is recommended to replace the other, even if it is not leaking .
,
1 . Confirm that the ToteTilter is in the 0° tilt position then disconnect the inbound airline at the pressure
regulator .
2 . Remove the pneumatic fitting from the actuator, and confirm that it can be reused .
3 . Loosen and remove retaining bolts . Once the retaining bolts are free, remove the actuator .
Note:
Keep the retaining bolts as the new actuators are not shipped with this hardware .
• 3/8”-16 UNC thread
• Actuator bolt hole depth is 5/8”
4 . Place the new actuator where the previous actuator was located .
5 . Install and tighten using the retaining bolts from step 3 .
• 3/8”-16 UNC thread
• Actuator bolt hole depth is 5/8”
• Tightening torque on the blind nut is 15-20 ft-lbs
6 . Install the pneumatic fitting on the new actuator .
• Use a small amount of Teflon or similar sealing tape on threads .
• Use caution avoid cross-threading the pneumatic fitting .
7 . Connect the airline to the pneumatic fitting on the newly installed actuator .