Installation

Fixed ToteTilter

It is advised not to affix the ToteTilter to the floor . If the ToteTilter is affixed to the floor, a potential entrap-

ment area may be formed that is not easily cleaned . 

1 . Place the ToteTilter on a level surface, leaving sufficient room for forklift travel .

Note:

 Shims, grout, etc . can be used to level the ToteTilter .

2 . The ToteTilter can be set into place using a forklift or other equipment-moving machine .
3 .  Mounting holes may have been requested at the time of purchase or may be drilled by the owner in the 

available space of the ToteTilter’s stationary base .

• Care should be taken when drilling holes in the stationary base to avoid damaging additional compo-

nents .
•  The owner is responsible for determining the most appropriate fastener to be used when mounting a 

ToteTilter .
•  At no point should holes be drilled or modifications made to the articulating frame of ToteTilter as it is a 

structural member . Altering the frame in any way can result in personal injury or death .
• It is not necessary to affix the ToteTilter to a permanent structure, assuming it is operated properly .

4 .  Connect the plant-provided airline to the ¼” NPT connection on the regulator (150 psig maximum inlet 

pressure) .

Note:

 The pressure regulator should be verified at the stated pressure for the specific unit . This informa-

tion can be found on the equipment tag .

WARNING

Operating ToteTilter with pressure regulator in excess of 30 psi can result in un-

safe conditions .

Care should be taken when loading and unloading ToteTilter to prevent                     

the unit from sliding out . 

CAUTION

WARNING

Never attempt to move the ToteTilter or ToteStand with a tote, intermediate bulk 

container, or other container placed on top .

Pneumatic connections should be made in accordance with local, state, and 

federal codes and standards .

CAUTION

Содержание ToteTilter

Страница 1: ...1 ww w TrueClean us TrueClean ToteTilterTM Installation Operation and Maintenance Manual...

Страница 2: ...3 Important Safety Information 3 Introduction 4 About This Manual 4 Warranty 5 Installation 6 ToteTilter 6 Fixed ToteTilter 7 Operation 8 Maintenance 9 Replacing Airlines 9 Replacing Actuators 10 Gre...

Страница 3: ...ace any missing labels right away Disclaimer of Liability TrueClean does not assume responsibility and expressly disclaims liability for loss damage or expenses that arise in any way from the installa...

Страница 4: ...ers are available with an optional ToteS tand that can provide additional functionality Refer to the ToteStand service manual for more informa tion The ToteTilter is designed to need little routine ma...

Страница 5: ...r to re quest their prepaid return to Seller Seller shall not be responsible for any transportation charges duty taxes freight labor or other costs The cost of removing and or installing products whic...

Страница 6: ...ded airline to the NPT connection on the regulator 150 psig maximum inlet pressure Note The pressure regulator should be verified at the stated pressure for the specific unit This informa tion can be...

Страница 7: ...At no point should holes be drilled or modifications made to the articulating frame of ToteTilter as it is a structural member Altering the frame in any way can result in personal injury or death It...

Страница 8: ...unloading the ToteTilter will gradually begin to raise stopping at its maximum angle Lowering Sequence 1 Press foot pedal again to begin the lowering sequence With an empty tote it may not be immediat...

Страница 9: ...is in the 0 tilt position then disconnect the inbound airline at the pressure regu lator 2 Remove a leaking airline by pressing the outer ring of the pneumatic fitting and pulling the airline outward...

Страница 10: ...ctuator Note Keep the retaining bolts as the new actuators are not shipped with this hardware 3 8 16 UNC thread Actuator bolt hole depth is 5 8 4 Place the new actuator where the previous actuator was...

Страница 11: ...ccordance with established manufacturing procedures If additional support is required please contact us at 800 654 5635 or 417 831 1411 1 Before applying new grease wipe as much foreign debris off of...

Страница 12: ...Compressed air Inlet Air line for actuator Flexible actuator Compressed air regulator Grease zerk Parts List 7 2 1293K11 Grease zerk 4 5 6 7 1 2 1 2 41 6 5 degree model W01 358 7731 10 degree model W...

Страница 13: ...13 Customer Notes...

Отзывы: