18
TRUE RESIDENTIAL
®
OVERL AY PANEL & OVERL AY PANEL GL A SS DOOR ADJUS TMENTS
PLEASE NOTE: DOOR HINGING ON TRUE PRODUCTS ARE NOT INTERCHANGEABLE. IT IS NEVER RECOMMEND TO
ATTEMPT MOVING DOOR HINGING TO THE OPPOSITE SIDE THE UNIT WAS BUILT WITH. THIS MAY CAUSE SERIOUS
DAMAGE AND HARM.
DOOR ADJUSTMENT UP AND DOWN - ALL VERSIONS
STEP 1 -
Make sure the unit is completely level and
in place.
STEP 2 -
Remove the bottom louver grill from the
unit. See image 1.
NOTE: A version grills are clipped in and B
version grills are held on with magnets.
STEP 3 -
With the door shut loosen the two 3/8-inch
bolts. See image 2 and 3.
STEP 4 -
While supporting the door, open slightly
and shift the door up or down on the
handle side. See image 4.
STEP 5 -
Hold the adjusted door and retighten
the two 3/8 inch bolts until very snug to
prevent the adjustment from coming loose.
DOOR A DJUSTMENT LEF T TO RIGHT
STEP 1 -
Loosen the top and bottom Phillips screws
(do not remove screws unless you want to
remove the door). See image 5 and 6.
STEP 2 -
Shift the entire door left or right to align to
desired position. See image 7.
STEP 3 -
While holding the door in position re-tighten
the upper and bottom screws to hold new
adjustment.
STEP 4 -
To adjust the upper only, loosen the two
screws on the upper hinge bracket and shift
door accordingly. See image 5.
STEP 5 -
To adjust the bottom only, loosen the two
screws on the bottom hinge bracket and
shift door accordingly. See image 6.
2
1
3
6
5
7
4