GDM HST02
www.truemfg.com
TEC_TM_158 | REV. A | EN
06/28/2022
Page 20 of 28
L A E C O N T R O L L E G E N D
Info/Set Point
Manual Activation/
Up Arrow
Manual Defrost/
Down Arrow
Stand-By/
Cancel
Compressor Running
Activation of 2
nd
Parameter Set
Alarm
Cabinet in Defrost
Evaporator Fan Running
Electronic Temperature Control (cont.)
Change the Set Point
Changing the set point adjusts the cabinet temperature to
keep optimal product temperature.
NOTE: The set point value is NOT the cabinet holding
temperature. To maintain proper operation within a safe
temperature range and prevent an alarm activation, it is
recommended to only change the value by a few degrees.
1.
Press and hold info
until the display shows the current
set point.
DO NOT RELEASE THE BUTTON!
2.
While holding info, press the up
or down
arrows
to adjust the setting.
3.
Release all buttons and wait for the control to display the
current cabinet temperature.
Initiate Manual Defrost
A manual defrost clears accumulated frost and ice from the
evaporator coil. The defrost will only terminate when a specific
preset temperature or duration has been met.
Press Manual Defrost
until the display shows
deF
.