Electronic Temperature Control (cont.)
L A E C O N T R O L L E G E N D
Info/Set Point
Manual Activation/
Up Arrow
Manual Defrost/
Down Arrow
Stand-By/
Cancel
Compressor Running
Activation of 2
nd
Parameter Set
Alarm
Cabinet in Defrost
Evaporator Fan Running
Enable the Product Loading & Servicing Delay
The Product Loading & Servicing Delay extends the 30-minute
window before the health safety timer activates. This feature
prevents the door from locking when loading or servicing the
cabinet. It is enabled automatically upon powering the unit
and following defrost events.
• Total Freezer Delay: 105 minutes
• Total Refrigerator Delay: 60 minutes
The Product Loading & Servicing Delay can also be manually
initiated with the instructions below.
1.
Press info
to show
hSt
.
2.
Press and hold info until the display shows
00
.
DO NOT RELEASE THE BUTTON!
3.
While holding info, press the up arrow until the display
shows
01
or your custom password.
4.
Release all buttons and wait for the control display to
alternate between
hSt
and
dLY
.
Test the Health Safety Lock
The Health Safety Lock locks the cabinet door when the
electronic control detects the cabinet temperature has been
above a preset temperature for 30 minutes.
1.
Press info
to show
hSt
.
2.
Press and hold info until the display shows
00
.
DO NOT RELEASE THE BUTTON!
3.
While holding info, press the up arrow until the display
shows
23
.
4.
Release all buttons. If operational, the Health Safety Lock
will activate.
5.
Clear the Health Safety Alarm. See “Clear the Health Safety