5
Specifies that the failover mode is transparent failover. With
transparent failover, controller A (the upper controller) port 1 is
active for units D0-D99. Controller A port 2 is passive for units
D100-D199. Controller B port 1 is passive for units D0-D99 and
controller B port 2 is active for units D100-D199.
Keep in mind that, for Tru64 UNIX Version 4.0F, you can configure
only units D0 through D7 and D100 through D107.
12. Execute the
show connections
command to determine the connection
name, and then use the connection name to set the operating system
and unit offset. In the following example, the connection name is
!NEWCON05
. The
!
(exclamation mark) is part of the name.
>
show connections
Connection
Unit
Name
Operating System
Controller
Port
Address
Status
Offset
!NEWCON05
TRU64_UNIX
THIS
1
000001
OL this
0
HOST_ID=1000-0000-C920-A6D9
ADAPTER_ID=1000-0000-C920-A6D9
>
set !NEWCON05 unit_offset = 0
1
>
set !NEWCON05 operating_system = TRU64_UNIX
2
>
restart this
3
>
restart other
3
1
Set the relative offset for LUN numbering to 0.
2
Specify that the host environment that is connected to the Fibre
Channel port is
TRU64_UNIX
.
3
Restart both controllers to cause all changes to take effect.
Use the
show this
and
show other
commands to verify the changes.
____________________
Note
_____________________
You change the connection name with the HSG80 CLI
RENAME
command. For example, you change the connection
name
!NEWCON05
to indicate that it is the first KGPSA on
host
pepecilli
as follows:
HSG80>
rename !NEWCON49 pep_pga_1
13. Set up the storage sets as required for the applications to be used.
4.3.1 Setting Up the HSG80 Array Controller for Arbitrated Loop
Section 4.3 describes settings that are common to both fabric and arbitrated
loop configurations. This section describes settings that are unique to setting
up the HSG80 controller for the arbitrated loop topology.
Installing Fibre Channel Hardware and Configuring the emx Driver 4–13