15
Connecting to tracking devices. Serial RS232 data format.
There are two settings, STANDARD and GEOTAB. Select STANDARD in Truck Setup
for all modems when Geotab is off. To Select GeoTab, only, in Truck Setup set to
ON. If it's OFF then it's in Standard output.
There are two ways to send serial data. Manually and Automatic. To manually
send data you must use the Print Button which will send
FLWC format to the Serial Port in either in Standard mode or GEOTAB. For
Automatic Select Interval time in seconds in Truck Setup.
You can also change Baud rate in the Truck Setup, default setting is 115200.
SDS is automatic data sent during a set time interval, and SDM is manually sent
data when print button is pressed.
FLWCV MAJOR.MINOR SDS/SDM*EQUIPMENT ID|VIRTUAL
SERIAL,AXLE,WEIGHT,1|
SERIAL#,AXLE,PRESSURE,TEMPERATURE,WEIGHT,1|
repeat for all Serial # then last one will have tow bars ||followed by Total
Weight of all axles followed by CR LF.
Sample Data output
FLWCV 3.20
SDM*TRUCK02|999999,1,0,0,0,1|*PEACE|684759540,5,35.1,29.2,2003,1||2000
FLWCV 3.20
SDS*TRUCK02|999999,1,0,0,0,1|*PEACE|684759540,5,35.1,29.2,2003,1||2000
Axle Group and Temperature ID.