![background image](http://html1.mh-extra.com/html/tru-test/id5000/id5000_service-manual_1173791016.webp)
ID5000, XR5000 Level 1 Service Manual
Issue 4, 8/2017
16
Service page / screen
Accessing the service login page
You can access the
Service
login page by pressing the key, then the
Settings
soft key. Press the
Next page
soft key until
the Service option appears, then press the
Service
soft key.
The
Service Log in
page will prompt you for a password. Enter
5000
, then press the
Log in
soft key.
Main service page items
Item
Description
Charge
The state of the battery charge
Battery Voltage
The voltage of the battery. Typically varies from 2700 mV (flat) to 3600 mV (fully
charged).
Battery Current
The current of the battery. Typically approx 2000 mA during charging, although this will
decrease when the battery approaches fully charged. Typically approx -800 mA during
discharge.
Charger Temperature
Ignore
Ambient Temperature
The temperature sensed from the thermistor located on the far right of the PCA.
Battery charging status
The charging status (e.g. Constant current, Not charging)
External power
Connected/Not connected
Ambient light
From the light sensor above the LCD. 0=dark, larger numbers are brighter.
ADC noise
A measure of the noise on the AD7192 load-cell ADC.
Raw ADC
Raw reading from the AM335x ADC channels, AIN0 to AIN7. These correspond to:
AIN0 - 3V3/2
AIN1 - 5V wall
AIN2 - 5V USB Device
AIN3 - Temperature
AIN4 - Cell Code 0
AIN5 - Cell Code 1
AIN6 - Main ID resistor
AIN7 - UI (keypad) ID resistor
Содержание ID5000