Overview of Functions

6

Fire damper

Open Closed

Operating Mode / Event

Mains connected

– Function status –

Mains not connected

Mains connected,
faulty electronics or
link L

7

/1-2 or

remote control or
smoke alarm not fitted

Pollution Level

1)

70 units

100 units

Test / Reset

– Inspection –

Smoke / Pollution

1)

100 units

3)

– Alarm status –

LED

Contact

LED

Contact

LED

Contact

LED

Contact

LED

Contact

LED

Contact

Signal

Red LED

Alarm

Blue LED

Velocity

Monitoring

Green LED

System

Monitoring

Terminal Strip

– L

9

6                 5

Terminal Strip

– L

9

4                 3

Terminal Strip

– L

9

2                 1

Terminal Strip

– L

3

2

3

1

Yellow LED

Pollution

Monitoring

With air flow: LED on

Without air flow: LED of

f

relay contact:

relay contact:

2)

2)

1) Pollution corresponding to diagnostic instrument display:

Up to

70 units – Normal range –

70 units – Warning level –

100 units – Alarm status –

2) May indicate a transitional state, e.g. caused by a cloud

of dust

3) An alarm triggered by smoke (event or maintenance) can

only be cancelled by pressing the button after the smoke
alarm head has cleared of smoke.

: LED on                          : LED flashing              : LED off

Содержание RM-O-VS

Страница 1: ...Smoke Detector Type RM O VS Approved by the German Institut f r Bautechnik 4 6 1 EN 3...

Страница 2: ...y condensation and water vapour can cause false alarms Warning limit for air flow 2 m s Warning limit for high pollution 70 10 units System monitoring electric fault EMC interference suppression to EN...

Страница 3: ...by an LED and closing relay contact The actual pollution value can be scanned directly at the smoke detector or on the remote control terminal using the diagnostic instrument Installation of a remote...

Страница 4: ...r to replace the smoke alarm an inspection opening should be provided on the upper or lower side of the air duct Optional electrical connections mains connection and connection to control device of fi...

Страница 5: ...trol device A on the fire damper to be controlled maximum switched power 250 V 10 A L1 Mains connection 230V 50 60 Hz L3 Control device connection volt free Switched power 250 V 10 A or 24 V 200 W L4...

Страница 6: ...Velocity Monitoring Green LED System Monitoring Terminal Strip L9 6 5 Terminal Strip L9 4 3 Terminal Strip L9 2 1 Terminal Strip L3 2 3 1 Yellow LED Pollution Monitoring With air flow LED on Without a...

Страница 7: ...rol devices on fire damper Response of smoke alarm to smoke aerosol e g cigarette smoke or smoke from smoke cartridge When the permitted concentration limit is exceeded the smoke alarm interrupts the...

Страница 8: ...ution level on the smoke alarm sampling chamber and the system electronics maintenance once year Scope of supply see page 2 Order Example Make TROX Type RM O VS Quantity 5 RM O VS Order Code Descripti...

Отзывы: