10
EN
dehumidifier TTK 655 S
Temperature limitation (overheating protection)
The device comes with a temperature limitation. It serves to
protect e.g. the compressor from overheating.
•
Upper temperature limit: +35 °C +/- 2 °C
•
Lower temperature limit: -3 °C +/- 2 °C
If the ambient temperature exceeds or falls below these limits,
the device automatically switches off the compressor; only the
fan will keep running. This feature protects the device from
overloading since high temperatures and high humidity levels
expose the device to extreme stresses. Moreover, drying is no
longer economical at such high temperatures and also poses
dangers for the inventory of the room to be dried. Please note
that the switch-off function works with a switch-on hysteresis of
-2 °C.
Operation with condensate pump (optional)
Note
The connection for the hose adapter is located in the
inside of the device.
Warning of electrical voltage
Always disconnect the condensate pump from the plug
connection before connecting the pump. This process
has to be carried out with the device disconnected
from the mains.
Otherwise there is a risk of an electric shock!
Optionally, the condensed water can also be discharged from
the device by means of a retrofitted condensate pump (see
chapter Available accessories). With a pump performance of up
to 50 m and a maximum pump height of 4 m, the condensate
can even be continuously discharged across storeys of a
building.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch off the device.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Storage chapter.
Available accessories
Warning
Only use accessories and additional equipment
specified in the instructions.
Using insertion tools or accessories other than those
specified in the instructions may cause a risk of injury.
Designation
Article number
Air filter TTK 655 S
7,160,000,009
External condensate pump
6,100,003,030
Protective cover
6,100,003,115
Dual counter for operating and kilowatt
hours
7,140,000,903
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damage.
•
Check the on-site fusing.
•
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
The device is running, but there is no formation of
condensate:
•
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
•
Ensure that the relative room humidity complies with the
technical data.
•
Check the air filter for dirt. If necessary, clean or replace
the air filter.
•
From the outside, check the condenser for dirt (see
chapter Maintenance). If the condenser is dirty, have it
cleaned by a specialist company or by Trotec.
•
The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The device is loud or vibrates:
•
Check whether the device is set up in a stable and upright
position.
Condensate is leaking:
•
Check the device for leaks.