dehumidifier TTK 655 S

Operation

Operating element

OFF

X

SSTTAATTU

USS

12

13

14

11

OFF

X

SSTTAATTU

USS

15

No. Designation

Meaning

11 Operating hours

counter

Indication of operating hours

12 Kilowatt hours counter,

MID-certified (optional)

Indication of energy consumption

13 Rotary switch

Selection of relative room
humidity

14 On/off switch

Switching the device on and off;
Is illuminated when the device is
switched on

15

Status

 LED

Indicates the operating status and
error messages

The device is optionally available with an operating element with
dual counter (see the image at the top right). The dual counter
registers both the operating hours and the energy consumption
and is certified according to the MID (Measuring Instruments
Directive 2004/22/EC). The kWh display is factory-calibrated
and may be used for accounting purposes. Contact your Trotec
customer service.
The 

Status

 LED (15) flashes once a second during normal

operation. If it flashes more frequently, lights up permanently or
does not light up at all, there might be a fault, see chapter
Errors and faults.

Switching the device on

Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.

1. Ensure that the condensation drain hose is properly

connected to the device and is free of damage.

2. Position a sufficiently large container (at least 20 litres; we

recommend a 60-litre mortar tub) beside the device and
insert the hose end. Check the filling level of the container
regularly.

3. Make sure that the condensation drain hose is installed

with a continuous decline.

4. Insert the mains plug into a properly secured mains

socket.

5. Switch on the device at the mains switch (14).
6. Ensure that the mains switch (14) is lit.
7. Adjust the room humidity level with the rotary switch (13).

Info

The compressor always starts with a delay. This
protects the compressor and thus increases its
lifetime. This delay is enabled during optional hygrostat
operation. If the room humidity exceeds the setting of
the selection switch, the compressor will only switch
back on after a delay. The fan keeps running
independently of the compressor.

Continuous operation mode

In continuous operation mode, the device dehumidifies the air
constantly, regardless of the humidity. To start continuous
operation mode, set the rotary switch (13) to Max.

Automatic defrost

If the room temperature is below 11 °C, the evaporator will
freeze during dehumidification. The device will then carry out an
automatic defrost. The duration of the defrost process can vary.

Do not switch off the device during automatic defrost. Do
not remove the mains plug from the mains socket.

Содержание TTK 655 S

Страница 1: ...TRT BA TTK655S TC2018 54 004 EN TTK 655 S EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER ...

Страница 2: ...S https hub trotec com id 41430 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference T...

Страница 3: ...e in rooms where there is no source of ignition e g open flames an active gas appliance or an electric heater Please note that the refrigerant is odourless Only install the device in compliance with the national installation regulations Observe the national gas regulations Only install operate and store the device TTK 655 S in a room measuring more than 4 m2 Store the device in a way that no mecha...

Страница 4: ...ualification A corresponding repair manual is available from the manufacturer upon request Residual risks Danger Refrigerant R454C H220 Extremely flammable gas H280 Contains gas under pressure may explode if heated P210 Keep away from heat sparks open flames and other ignition sources No smoking P381 Eliminate all ignition sources if safe to do so P403 Store in a well ventilated place Warning of e...

Страница 5: ...ctor into an external container or drain Optionally the condensed water can also be discharged from the device by means of a retrofitted condensate pump see chapter Installing the condensate pump For easy operation and transport the device is fitted with an on off switch an operating hours counter a transport handle and wheels Two feet with rubber buffers prevent the device from rolling away The d...

Страница 6: ...condensation drain hose see chapter Maintenance Do not use the power cable to drag the device Do not incline the device by more than 45 for otherwise the device could be damaged Only wheel the device on a level and smooth surface Note After unpacking the device remove the two lower screws and adjust the transport handle Afterwards reinsert the screws This only needs to be carried out the very firs...

Страница 7: ...et Drain any possibly remaining condensate When the device is not being used observe the following storage conditions Only store the device in a room measuring more than 4 m2 Only position the device in rooms where there is no source of ignition e g open flames an active gas appliance or an electric heater dry and protected from frost and heat in an upright position where it is protected from dust...

Страница 8: ...cially when positioning the device in the middle of the room Use cable bridges Make sure that extension cables are completely unrolled When positioning the device keep a sufficient distance to heat sources Make sure that no curtains or other objects interfere with the air flow When positioning the device particularly in wet areas secure it locally with an RCD residual current device which complies...

Страница 9: ...sure that the condensation drain hose is properly connected to the device and is free of damage 2 Position a sufficiently large container at least 20 litres we recommend a 60 litre mortar tub beside the device and insert the hose end Check the filling level of the container regularly 3 Make sure that the condensation drain hose is installed with a continuous decline 4 Insert the mains plug into a ...

Страница 10: ...onto the mains plug while pulling the power cable out of the mains socket Clean the device according to the Maintenance chapter Store the device according to the Storage chapter Available accessories Warning Only use accessories and additional equipment specified in the instructions Using insertion tools or accessories other than those specified in the instructions may cause a risk of injury Desig...

Страница 11: ...have it cleaned by a specialist company for cooling and air conditioning or by Trotec Your device still does not operate correctly after these checks Please contact the customer service If necessary bring the device to a specialist company for cooling and air conditioning or to Trotec for repair Error codes The Status LED 15 can indicate the following statuses during operation Error message Meanin...

Страница 12: ...and or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace the air filter Chec...

Страница 13: ...d place The entire refrigerant circuit is a maintenance free hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air conditioning or by Trotec Safety signs and labels on the device Check the safety signs and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean the housing with a soft damp ...

Страница 14: ...enance If you want to continue using the device Reconnect the device to the mains If you do not intend to use the device for a considerable time Store the device according to the Storage chapter Technical annex Technical data Parameter Value Model TTK 655 S Dehumidification performance 30 C 80 RH 91 l 24 h Dehumidification performance max 150 l 24 h Operating range temperature 5 32 C Operating ran...

Страница 15: ...IGH LEVEL FLOAT SWITCH LOW LEVEL FLOAT SWITCH PURGE SWITCH Black Black Blue Brown Green Yellow PLUG Brown Red Black Motor Water Pump Optional P F C NA CC NF N J9 JP11 J5 PCB Status 2 C NTC 10kÙ NC contact NO contact SHUNT 3 2 1 Time Counter Standard M2 M2 M1 M1 Y Y L RC H N J7 3 C 32 C NTC 10kÙ S1 0 1 R R E Earthing M2 Fan motor N Common Line Y Two Way Valve L Line RC Running Capacitor S1 On Off S...

Страница 16: ...7 3 C 32 C 2 C NTC 10kÙ NTC 10kÙ NC contact NO contact 4 P SHUNT 3 2 1 S1 0 1 Time Energy Counter HE Iavg 5A N Lout Lin M2 M2 M1 M1 Y Y RC F C NA CC NF N Counter counting energy and time downstream the main switch Wiring diagram with condensates pump reseting the PCB 220 240V 50Hz 220 240V 50Hz PCB Status R R E Earthing M2 Fan motor N Common Line Y Two Way Valve L Line RC Running Capacitor S1 On O...

Страница 17: ...position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions 5 3 37 40 38 29 46 23 6 20 39 33 41 36 34 11 13 12 47 20 15 4 18 19 21 31 1 2 24 22 48 16 17 7 44 43 8 10 35 32 30 27 28 25 26 14 42 45 9 ...

Страница 18: ... 22 Running capacitor 38 Time counter 7 Left side panel 23 Heat exchanger 39 Hygrostat 8 Dummy panel for optional condensates pump 24 Water pan 40 Humidistat knob 9 1 4 turn lock 25 Hose fitting 41 Electronic controller 10 Structural foot 26 Hidraulic Plug 42 Electronic controller status LED 11 Rubber feet 27 Defrost valve 43 Defrost sensor 12 Wheels axe 28 Defrost valve coil 44 Ambient temperatur...

Страница 19: ...rotec com id 41430 Declaration of conformity in accordance with the EC Machinery Directive 2006 42 EC Annex II Part 1 Section A Herewith we Trotec GmbH declare that the machinery designated below was developed constructed and produced in compliance with the requirements of the EC Machinery Directive in the version 2006 42 EC Product model product TTK 655 S Product type dehumidifier Year of manufac...

Страница 20: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: