EN
9
dehumidifier TTK 655 S
Operation
Operating element
OFF
X
SSTTAATTU
USS
12
13
14
11
OFF
X
SSTTAATTU
USS
15
No. Designation
Meaning
11 Operating hours
counter
Indication of operating hours
12 Kilowatt hours counter,
MID-certified (optional)
Indication of energy consumption
13 Rotary switch
Selection of relative room
humidity
14 On/off switch
Switching the device on and off;
Is illuminated when the device is
switched on
15
Status
LED
Indicates the operating status and
error messages
The device is optionally available with an operating element with
dual counter (see the image at the top right). The dual counter
registers both the operating hours and the energy consumption
and is certified according to the MID (Measuring Instruments
Directive 2004/22/EC). The kWh display is factory-calibrated
and may be used for accounting purposes. Contact your Trotec
customer service.
The
Status
LED (15) flashes once a second during normal
operation. If it flashes more frequently, lights up permanently or
does not light up at all, there might be a fault, see chapter
Errors and faults.
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
1. Ensure that the condensation drain hose is properly
connected to the device and is free of damage.
2. Position a sufficiently large container (at least 20 litres; we
recommend a 60-litre mortar tub) beside the device and
insert the hose end. Check the filling level of the container
regularly.
3. Make sure that the condensation drain hose is installed
with a continuous decline.
4. Insert the mains plug into a properly secured mains
socket.
5. Switch on the device at the mains switch (14).
6. Ensure that the mains switch (14) is lit.
7. Adjust the room humidity level with the rotary switch (13).
Info
The compressor always starts with a delay. This
protects the compressor and thus increases its
lifetime. This delay is enabled during optional hygrostat
operation. If the room humidity exceeds the setting of
the selection switch, the compressor will only switch
back on after a delay. The fan keeps running
independently of the compressor.
Continuous operation mode
In continuous operation mode, the device dehumidifies the air
constantly, regardless of the humidity. To start continuous
operation mode, set the rotary switch (13) to Max.
Automatic defrost
If the room temperature is below 11 °C, the evaporator will
freeze during dehumidification. The device will then carry out an
automatic defrost. The duration of the defrost process can vary.
•
Do not switch off the device during automatic defrost. Do
not remove the mains plug from the mains socket.