This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.

Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!

The electrical connection must correspond to the
specifications in chapter Technical data.

Insert the mains plug into a properly secured mains
socket.

Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. 
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!

When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
data chapter.

Make sure that the air inlet and outlet are not obstructed.

Make sure that the suction side is kept free of dirt and
loose objects.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Only transport the device in an upright position with an
emptied condensation tank or drain hose.

Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!

Intended use

Only use the device for drying and dehumidifying room air, while
adhering to and following the technical data.
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry.
Intended use comprises:

dehumidifying and drying:

– living rooms, bedrooms, bathrooms and basements
– laundries, holiday homes, camper vans, boats

maintaining the dryness of:

– storage spaces, archives, laboratories, garages
– bathrooms, wash rooms, changing rooms etc.

Improper use

The device is not intended for industrial use.

Do not place the device on wet or flooded ground.

Do not place any objects, e.g. clothing, on the device.

Do not use the device outdoors.

Any unauthorised modifications, alterations or structural
changes to the device are forbidden.

Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.

Personnel qualifications

People who use this device must:

be aware of the dangers that occur when working with
electric devices in damp areas.

have read and understood the operating manual, especially
the Safety chapter.

Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.

Содержание TTK 53 E

Страница 1: ...TRT BA TTK53E TTK72E TC2016 09 004 EN TTK 53 E TTK 72 E EN OPERATING MANUAL DEHUMIDIFIER ...

Страница 2: ...TK 53 E https hub trotec com id 42189 TTK 72 E https hub trotec com id 41804 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all war...

Страница 3: ...chapter Make sure that the air inlet and outlet are not obstructed Make sure that the suction side is kept free of dirt and loose objects Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition Only transport the device in an upright position with an emptied condensation tank or drain hose Discharge the collected condensate b...

Страница 4: ...he evaporator and to the condenser located behind it The air is cooled at the cold evaporator until it is below the dew point Water vapour contained in the room air precipitates on the evaporator fins as condensation or rime The dehumidified cooled air is slightly warmed at the condenser and blown out again The drier air thus conditioned mixes with the air in the room The humidity in the room wher...

Страница 5: ... 3 4 5 6 7 8 9 2 3 10 No Designation 1 Control panel 2 Transport handle 3 Wheels 4 Air inlet with air filter 5 Condensation drain hose connection 6 Condensation tank 7 Air filter 8 Condensation drain hose 9 Air outlet 10 Colour LED for current room humidity ...

Страница 6: ...ank prior to storage Hold onto the mains plug while pulling the power cable out of the mains socket Drain any possibly remaining condensate When the device is not being used observe the following storage conditions dry and protected from frost and heat in an upright position where it is protected from dust and direct sunlight with a cover to protect it from invasive dust if necessary Place no furt...

Страница 7: ...air filter Note Do not operate the device without an inserted air filter Without the air filter the inside of the device will be heavily contaminated This could reduce the performance and result in damage to the device Make sure that the air filter is installed before switching the device on Inserting the condensation tank Ensure that the float inside the condensation tank is inserted correctly En...

Страница 8: ...o Designation Meaning 16 MODE button Selection button for operating modes Automatic mode Dehumidification additionally continuous operation Laundry drying function Ventilation 17 STAND BY button Power button Switches the device on or off 18 OPERATION indication Illuminated when the device is switched on 19 AUTOMATIC indication Automatic mode is active 20 CONTINUOUS indication Dehumidification mode...

Страница 9: ...UTOMATIC indication 19 is illuminated Laundry drying function The device may be used to dry clothes in a more timely manner When positioning the device or a clothes horse please observe the minimum distances specified in the technical data The device dehumidifies the air constantly and regardless of the relative room humidity The fan runs at the highest speed The relative room humidity and the fan...

Страница 10: ... Wait for approx 5 seconds in order to save the setting ð The TIMER indication 24 is illuminated ð The relative room humidity is indicated in the segment display 13 again ð The device switches off after the set period of time Memory function The device memorizes the last selected operating mode and in dehumidification mode 20 also the set room humidity during short power failures If the timer was ...

Страница 11: ... vary Do not switch off the device during automatic defrost Do not remove the mains plug from the mains socket Drying laundry In addition the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces When positioning the device or a clothes horse please observe the minimum distances specified in the technical data For drying laundry the following values shou...

Страница 12: ...the outside check the condenser for dirt see chapter Maintenance If the condenser is dirty have it cleaned by a specialist company or by Trotec The device might carry out an automatic defrost During automatic defrost the device does not dehumidify The device is loud or vibrates Check whether the device is set up in a stable and upright position Condensate is leaking Check the device for leaks The ...

Страница 13: ...hs at least annually Check air inlets and outlets for dirt and foreign objects and clean if necessary X X Clean the exterior X X Visually check the inside of the device for dirt X X Check the air filter for dirt and foreign objects and clean or replace if necessary X X Replace the air filter X Check for damage X Check the attachment screws X X Test run X Empty the condensation tank and drain hose ...

Страница 14: ...or dirt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace the air filter Check for damage Check the attachment screws Test run Empty the condensation tank and drain hose Comments 1 Date Signature 2 Date Signature 3 Date Signature 4 Date Signature 5 Date Signature 6 Date Signature 7 Date Signature 8 Date Signature 9 Date Signature 10 Date Signature 11 Date ...

Страница 15: ...e inside of the device for dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company for cooling and air conditioning or by Trotec 5 Put the air filter back in Refrigerant circuit The entire refrigerant circuit is a maintenance free hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air conditioning ...

Страница 16: ...tank into the device Make sure not to damage the float when inserting or removing the condensation tank In doing so make sure that the float is positioned correctly In doing so make sure that the condensation tank is inserted correctly for otherwise the device cannot be switched back on Activities required after maintenance If you want to continue using the device Leave the device to rest for 12 t...

Страница 17: ... The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return option...

Страница 18: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: