13
EN
Operating manual – gas heater fan TGH 10 E / TGH 15 E / TGH 30 E
Technical annex
Technical data
Parameter
Value
Model
TGH 10 E
TGH 15 E
TGH 30 E
Heating capacity
10 kW
15 kW
30 kW
Gas consumption
730 g/h
1,090 g/h
2,180 g/h
Type of gas
Propane
Propane
Propane
Operating pressure
0.7 bar
0.7 bar
0.7 bar
Gas cylinder capacity
≤ 33 kg
≤ 33 kg
≤ 33 kg
Air flow rate
320 m³/h
320 m³/h
650 m³/h
Air outlet temperature
(1.5 m distance)
84.5 °C
79.5 °C
75.6 °C
Operating range
-15 °C to +30 °C
-15 °C to +30 °C
-15 °C to +30 °C
Sound pressure level
(1 m distance)
48 dB(A)
48 dB(A)
65 dB(A)
Mains connection
220-240 V / 50Hz
220-240 V / 50Hz
220-240 V / 50Hz
Max. power input
10 kW
15 kW
30 kW
Nominal current consumption
0.23 A
0.23 A
0.29 A
Protection class
I
I
I
Plug type
CEE 7/4
CEE 7/4
CEE 7/4
Cable length
1.6 m
1.6 m
1.6 m
Dimensions
(depth x width x height)
380 x 190 x 305 (mm)
380 x 190 x 305 (mm)
475 x 225 x 360 (mm)
Weight
4 kg
4 kg
6 kg
Overheating protection
95 °C
80 °C
75 °C
Ignition head
Piezo igniter
Piezo igniter
Piezo igniter
Flame failure protection
x
x
x
Minimum distance to walls and
other objects
top:
rear:
sides:
front:
2 m
2.5 m
2 m
3.5 m
2 m
2.5 m
2 m
3.5 m
2 m
2.5 m
2 m
3.5 m
Min. room size
100 m³
150 m³
300 m³
Min. ventilation cross-section
250 cm³
375 cm³
750 cm³