background image

EN

2

Operating manual – turbo fan TFV 10 / TFV 20 / TFV 30

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and / or serious injury.

Save all warnings and instructions for future
reference.

This appliance can be used by children aged from
8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.

Do not use the device in potentially explosive rooms.

Do not use the device in aggressive atmosphere.

Set the device up in an upright and stable position.

Let the device dry out after a wet clean. Do not operate it
when wet.

Do not use the device with wet or damp hands.

Do not expose the device to directly squirting water.

Never insert any objects or limbs into the device.

Do not cover or transport the device during operation.

Do not sit on the device.

This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.

Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!

The electrical connection must correspond to the
specifications in chapter Technical data.

Insert the mains plug into a properly secured mains
socket.

Observe the technical data when selecting extensions to
the power cable. Completely unroll the extension cable.
Avoid electrical overload.

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. 
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk.

Observe the storage and operating conditions as given in
the Technical data chapter.

Ensure that the air inlet and outlet are not obstructed.

Make sure that there are no loose items located in the
immediate surroundings of air inlet and air outlet.

Intended use

The devices 

TFV 10

 / 

TFV 20

 / 

TFV 30

 may be used for

generating a broad near-ground air current with a high air
circulation for the accelerated drying of flooring or to assist in
drying walls and floors after water damage or else for
construction drying. All other applications are considered
improper use.

Improper use

The turbo fan is not suited for installation in fluids or on flooded
or boggy grounds. Any unauthorised changes, modifications or
alterations to the device are forbidden.

Personal protective equipment

Wear hearing protection

Wear appropriate hearing protection when working
with the device.

Personnel qualifications

People who use this device must:

have read and understood the operating manual, especially
the Safety chapter.

Содержание TFV 20

Страница 1: ...TRT BA TFV10 TFV20 TFV30 TC 002 EN TFV 10 TFV 20 TFV 30 EN OPERATING MANUAL TURBO FAN ...

Страница 2: ...ry or death Caution This signal word indicates a hazard with a low risk level which if not avoided can result in minor or moderate injury Note This signal word indicates important information e g material damage but does not indicate hazards Info Information marked with this symbol helps you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates ...

Страница 3: ...ctric cables or the power connection are damaged The electrical connection must correspond to the specifications in chapter Technical data Insert the mains plug into a properly secured mains socket Observe the technical data when selecting extensions to the power cable Completely unroll the extension cable Avoid electrical overload Before carrying out maintenance care or repair work on the device ...

Страница 4: ... description The devices TFV 10 TFV 20 TFV 30 were designed for a very high air flow rate They may be used for drying carpets buildings or screed as well as for the ventilation of poorly accessible intermediate spaces Owing to the high air circulation the devices can also be used to control excessive humidity levels The fan is also very effective for the additional air circulation when heating lar...

Страница 5: ... fan stage selection 2 Operating hours counter 3 Transport handle 4 Air outlet 5 Skids 6 Air inlet 7 Cable holder TFV 20 1 11 8 4 3 6 5 7 No Designation 1 Switch for fan stage selection 3 Transport handle 4 Air outlet 5 Skids 6 Air inlet 7 Cable holder 8 Service power socket 11 Dual counter operating and kilowatt hours ...

Страница 6: ... Hold onto the mains plug while pulling the power cable out of the mains socket Do not use the power cable to drag the device After transporting the device observe the following Set up the device in an upright position after transport Storage Before storing the device observe the following When the device is not being used observe the following storage conditions dry and protected from frost and h...

Страница 7: ...al three way hose distributor Info Seal off unused connections by means of suitable sealing caps and possibly with hose clamps to prevent a decrease in the air flow rate Info The procedure of fitting a hose distributor is described below using the example of a three way hose distributor that is connected to the TFV 30 however it applies accordingly to the TFV 20 and a two way hose distributor 1 Op...

Страница 8: ...hoses for tight fit Start up Positioning Set the device up separately and in a stable position The device can be variably positioned in a way to allow an air discharge at an angle of 0 45 or 90 0 45 90 Connecting the power cable Insert the mains plug into a properly secured mains socket Operation Operating elements TFV 10 1 No Designation 1 Switch for fan stage selection ...

Страница 9: ...fan stage stage 1 LOW stage 2 MEDIUM stage 3 HIGH ð The device is switched on Dual counter TFV 20 and TFV 30 The devices TFV 20 TFV 30 are equipped with a dual counter 11 The operating hours are indicated in the upper section of the counter the kilowatt hours are displayed just below The kWh counter is certified according to MID The LED 10 is illuminated as soon as a current flow is established Us...

Страница 10: ...r service The fan is not running Check whether the device is switched on Check the power connection Check the power cable and mains plug for damages Check the on site fusing Note Wait for at least 3 minutes after maintenance and repair work Only then switch the device back on Your device still does not operate correctly after these checks Please contact the customer service If necessary bring the ...

Страница 11: ...30 V 50 Hz 5 2 A Power input max 0 85 kW Stat air pressure freely blowing max 425 Pa Protection type IP22 Sound level distance 3 m Stage 1 Stage 2 Stage 3 73 5 dB A 80 8 dB A 86 2 dB A Dimensions L x W x H 440 x 440 x 440 mm Weight 18 5 kg Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the hou...

Страница 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: